Excitation filter
Selects the excitation band and suppresses source output in the fluorescence collection band.
- Selection focus
- Source centre wavelength, bandwidth, passband transmission, out-of-band blocking
Fluorescence guidance · Endoscopic imaging
Excitation cleanup, near-infrared fluorescence collection and visible-light separation — matched to the spectral needs of endoscopic imaging systems.
ICG fluorescence imaging has to collect a relatively weak near-infrared signal against a strong excitation background. A well-matched set of excitation filter, emission filter and dichroic mirror helps reduce spectral crosstalk and provides a reliable optical basis for fluorescence imaging.

ICG emits fluorescence when excited with appropriate near-infrared light. Filters work together with the light source, optical path and detector to separate the target fluorescence from excitation light and other background.
| System concern | Filter design focus |
|---|---|
| Excitation leak raising background in the fluorescence channel | Blocking depth in the excitation band and how the filters work together |
| Weak fluorescence signal limiting collection efficiency | Passband chosen against the ICG emission spectrum and detector response |
| White-light and fluorescence dual-channel imaging | Coordinating visible and NIR transmission according to the split architecture |
Image quality is determined by the light source, optics, detector and image processing together — filters should be evaluated as part of the complete system.
NIR light source → excitation filter → illumination path → target tissue
Returned light → collection optics → beam-splitting component (per system) → emission filter → NIR detector
The spectral behaviour of ICG varies with medium and environment. Selection should weigh the actual source spectrum, target fluorescence range, angle of incidence and detector response when fixing passbands and blocking regions.
Mechanism and filter configuration details: What is an ICG fluorescence navigation endoscope filter?
Excitation, emission and beam-splitting elements each have a role; the combination follows the system architecture.
Selects the excitation band and suppresses source output in the fluorescence collection band.
Passes the target fluorescence while suppressing reflected or scattered excitation light.
Reflects or transmits selected bands as the optical path requires.
The emission side can be evaluated as long-pass or bandpass depending on the system; dichroic configuration depends on the illumination and collection architecture — not every system needs the same filter set.
Assess transition width and spectral overlap against the real source bandwidth and fluorescence collection range.
Read the transmission curve and the optical density (OD) curve together, with the wavelength range stated for each.
Interference filter spectra shift with illumination geometry. Provide the working angle, angular distribution and polarisation condition.
When white light and fluorescence are captured together, coordinate beam splitting, visible colour rendition and NIR crosstalk.
Confirm outline, thickness, clear aperture and mounting to the available space. Where cleaning, disinfection or sterilisation is involved, specify requirements according to the actual mounting position and verify them.
The table below defines what should be published per model; fill in actual values rather than unverified blanket commitments.
| Specification | Range we can produce |
|---|---|
| Excitation band | Selected from the actual ICG spectrum and light source; 760 nm is only one candidate |
| Emission collection | Longpass or bandpass evaluated from the emission spectrum and excitation leakage; the 830 nm peak is not treated as a cut-on edge |
| Dichroic mirror | 800 nm cut-off (780 nm reflected, 820 nm transmitted) |
| Blocking depth | OD4-OD5, keeping excitation light out of the camera |
| Transmission | Excitation >60%; emission >80% |
| Exposure match | High transmission supports short-exposure dynamic imaging |
| Stray light control | Multilayer blocking against ambient light; assessed separately when a white-light channel is used |
These are the ranges we normally produce. Requirements beyond them can be evaluated from drawings; final values are confirmed by sample and datasheet.

Filter elements configured around NIR fluorescence collection.

Coordinating visible and NIR optical paths.

Selection against space, imaging beam and mounting position.

Comparing filter combinations and verifying system spectra.
Requirement intake → spectral and mechanical assessment → sample approval → system testing → specification release
Source spectrum, target band, angle of incidence, mounting conditions
Passband, blocking depth, substrate and dimensional feasibility
Samples built to agreed parameters with measured curves
Verification inside the customer optical system
Freeze model, inspection items and supply terms
Providing the source spectrum, target collection band, optical layout and mounting conditions helps identify the right filter combination. Sample validation should be done in the real system, focusing on excitation leak, fluorescence collection, uniformity across the field and dual-channel crosstalk.