Fluorescence guidance · Endoscopic imaging

ICG Fluorescence Navigation Endoscope Filters

Excitation cleanup, near-infrared fluorescence collection and visible-light separation — matched to the spectral needs of endoscopic imaging systems.

ICG fluorescence imaging has to collect a relatively weak near-infrared signal against a strong excitation background. A well-matched set of excitation filter, emission filter and dichroic mirror helps reduce spectral crosstalk and provides a reliable optical basis for fluorescence imaging.

800–850 nm NIR fluorescence collection window (per system)
OD 6 Excitation-band blocking (upgrade options available)
45° Typical dichroic working angle
ICG fluorescence endoscopy system with filter configuration (schematic)
Imaging and layout shown are schematic, not clinical results

Controlling spectral transmission from excitation to detection

ICG emits fluorescence when excited with appropriate near-infrared light. Filters work together with the light source, optical path and detector to separate the target fluorescence from excitation light and other background.

System concern Filter design focus
Excitation leak raising background in the fluorescence channel Blocking depth in the excitation band and how the filters work together
Weak fluorescence signal limiting collection efficiency Passband chosen against the ICG emission spectrum and detector response
White-light and fluorescence dual-channel imaging Coordinating visible and NIR transmission according to the split architecture

Image quality is determined by the light source, optics, detector and image processing together — filters should be evaluated as part of the complete system.

ICG fluorescence optical path and filter configuration

① Excitation path NIR source Excitation filter Illumination Dichroic 45° Target tissue ② Collection path Collection optics Emission LP / BP NIR detector White-light branch Schematic only; beam-splitting depends on system architecture
① Excitation

NIR light source → excitation filter → illumination path → target tissue

② Collection

Returned light → collection optics → beam-splitting component (per system) → emission filter → NIR detector

③ White-light imaging channel (branch)

The spectral behaviour of ICG varies with medium and environment. Selection should weigh the actual source spectrum, target fluorescence range, angle of incidence and detector response when fixing passbands and blocking regions.

T % nm 750800 850900950 Excitation ICG emission Emission (LP) transition
The chart overlays excitation spectrum, ICG fluorescence spectrum and filter transmission to show their relative positions; refer to measured reports for actual values.

Mechanism and filter configuration details: What is an ICG fluorescence navigation endoscope filter?

Configuring ICG filters to match the optical path

Excitation, emission and beam-splitting elements each have a role; the combination follows the system architecture.

01

Excitation filter

Selects the excitation band and suppresses source output in the fluorescence collection band.

Selection focus
Source centre wavelength, bandwidth, passband transmission, out-of-band blocking
02

Emission filter

Passes the target fluorescence while suppressing reflected or scattered excitation light.

Selection focus
Passband range, blocking depth in the excitation region, transition width, angle of incidence

The emission side can be evaluated as long-pass or bandpass depending on the system; dichroic configuration depends on the illumination and collection architecture — not every system needs the same filter set.

Selection goes beyond centre wavelength

  1. 01

    Separation between excitation and fluorescence

    Assess transition width and spectral overlap against the real source bandwidth and fluorescence collection range.

  2. 02

    Passband transmission and blocking depth

    Read the transmission curve and the optical density (OD) curve together, with the wavelength range stated for each.

  3. 03

    Angle of incidence and beam cone

    Interference filter spectra shift with illumination geometry. Provide the working angle, angular distribution and polarisation condition.

  4. 04

    Dual-channel imaging requirements

    When white light and fluorescence are captured together, coordinate beam splitting, visible colour rendition and NIR crosstalk.

  5. 05

    Mechanical and operating environment

    Confirm outline, thickness, clear aperture and mounting to the available space. Where cleaning, disinfection or sterilisation is involved, specify requirements according to the actual mounting position and verify them.

Spectral parameters and mechanical specifications

The table below defines what should be published per model; fill in actual values rather than unverified blanket commitments.

Specification Range we can produce
Excitation band Selected from the actual ICG spectrum and light source; 760 nm is only one candidate
Emission collection Longpass or bandpass evaluated from the emission spectrum and excitation leakage; the 830 nm peak is not treated as a cut-on edge
Dichroic mirror 800 nm cut-off (780 nm reflected, 820 nm transmitted)
Blocking depth OD4-OD5, keeping excitation light out of the camera
Transmission Excitation >60%; emission >80%
Exposure match High transmission supports short-exposure dynamic imaging
Stray light control Multilayer blocking against ambient light; assessed separately when a white-light channel is used
T%nm 750800850900 Excitation 785/40 Emission 830 LP Schematic, not measured data
Transmission spectrum: passband and split relationship (schematic curve)
ODnm 64210.5 700750800850 Blocking ≥ OD6 Schematic, not measured data
OD spectrum: blocking performance in the excitation region (schematic curve)
Outline Ø D Clear aperture Thickness t Tolerance per project Schematic; mounting ring depends on available space
Dimensional drawing: for assembly fit check (schematic)

Custom manufacturing capability

These are the ranges we normally produce. Requirements beyond them can be evaluated from drawings; final values are confirmed by sample and datasheet.

Fluorescence laparoscope systems

Fluorescence laparoscope systems

Filter elements configured around NIR fluorescence collection.

White-light / fluorescence dual-channel modules

White-light / fluorescence dual-channel modules

Coordinating visible and NIR optical paths.

Endoscope camera heads and optical adapter modules

Endoscope camera heads and optical adapter modules

Selection against space, imaging beam and mounting position.

Research and prototype validation platforms

Research and prototype validation platforms

Comparing filter combinations and verifying system spectra.

From requirement to sample validation

Requirement intake → spectral and mechanical assessment → sample approval → system testing → specification release

  1. 1

    Requirement intake

    Source spectrum, target band, angle of incidence, mounting conditions

  2. 2

    Spectral and mechanical assessment

    Passband, blocking depth, substrate and dimensional feasibility

  3. 3

    Sample approval

    Samples built to agreed parameters with measured curves

  4. 4

    System testing

    Verification inside the customer optical system

  5. 5

    Specification release

    Freeze model, inspection items and supply terms

Providing the source spectrum, target collection band, optical layout and mounting conditions helps identify the right filter combination. Sample validation should be done in the real system, focusing on excitation leak, fluorescence collection, uniformity across the field and dual-channel crosstalk.

Frequently asked questions

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide