Small-animal imaging · Fluorescence & bioluminescence · Near-infrared

In Vivo Imaging Filters

For fluorescence, bioluminescence and near-infrared imaging — matched to low-light detection and multi-band collection.

For small-animal optical imaging we configure excitation filters, emission filters and beam-splitting elements around the fluorescent probe or bioluminescent reporter, the light source and the camera response. Passband and blocking design balance target-signal collection, background suppression and multi-channel separation.

  • Low-light collection
  • Excitation blocking
  • Multi-band acquisition
5 imaging modes Fluorescence / bioluminescence / NIR / multispectral / NIR-II
Fluorescence + emission Two paths configured separately
Reports included Transmission, blocking curves and lot records
Small-animal imaging system, filters and multi-band spectra (schematic)
Instrument, filters and spectra are schematic; pseudo-colour images use licensed material and are not a claim on imaging performance or experimental results

Each imaging mode calls for its own filter configuration

Define the imaging mode first, then the combination of excitation, emission and beam-splitting elements.

Imaging mode Signal origin Filter priorities
Fluorescence imaging Probe or fluorescent protein excited by an external source Excitation band selection, emission collection and excitation blocking
Bioluminescence imaging Biochemical reaction of a reporter system Broad-band collection or selected emission bands as required
Near-infrared fluorescence imaging NIR probe emission after excitation Matching probe spectrum, tissue background and detector response
Multispectral imaging Target signal collected in several bands Channel coverage, response calibration and spectral separation
NIR-II / SWIR research imaging Emission of the corresponding NIR probe Band fit across filters, lens and detector as one chain

Near-infrared and multispectral describe a wavelength range or an acquisition method; they can be combined with fluorescence or bioluminescence modes.

Pass the target signal, keep non-target light off the detector

In vivo optical signals are usually weak, while background arises from reflected and scattered excitation light, tissue autofluorescence and overlapping probes. Filter design has to consider signal level, background position and acquisition method together.

System concern Filter design focus
Weak target signal Passband position, effective bandwidth and transmission
Background from reflected or scattered excitation Blocking performance at the emission side over the real excitation range
Tissue autofluorescence reducing contrast Target-to-background spectral relationship and multi-band acquisition plan
Overlapping signals from several probes Channel choice and the acquisition set required for unmixing
Response varies across a large field Beam cone angle, angle of incidence and clear-aperture uniformity
Background rises during long exposures Check light leaks, material background and system stray light

Filters reduce part of the non-target light but cannot remove every background component that shares the target band. Image quality depends on probe, tissue, illumination, lens, camera and processing method.

Optical paths for fluorescence and bioluminescence imaging

Fluorescence imaging needs excitation and emission sides to work together; bioluminescence needs no external excitation and may stay broad-band or add band selection.

Fluorescence: excitation and emission sides work together Source source Excitation excitation Illumination illumination Object object Collection collection Emission emission Camera camera Excitation side: defines light reaching the sample Emission side: defines what the camera sees Bioluminescence: no external excitation needed Object object emission Collection optics collection optics Optional emission filter / wheel optional emission Camera camera Schematic: coaxial layout, dichroic and filter wheel follow the real system Bioluminescence needs no excitation light; broad-band collection preserves photon flux
Schematic only; coaxial layout, dichroic and filter wheel follow the actual system.
Fluorescence path
Sourceexcitation filterillumination opticsobjectcollection opticsemission filtercamera
Bioluminescence path
Object emissioncollection opticsoptional emission filter / filter wheelcamera
01

Excitation side

The excitation filter sets the spectrum reaching the sample; also check its leakage in the detection band.

02

Emission side

The emission filter defines what the camera sees and must block the real excitation range.

03

Coaxial layout

A coaxial path can add a dichroic as designed; reflective and transmissive illumination are drawn separately.

04

Bioluminescence

No excitation filter is needed without external excitation; broad-band collection preserves photon flux.

Bioluminescence collection needs no external excitation light. Broad-band collection makes the most of photon flux; when reporter signals must be separated or spectral information is needed, band-resolved detection can be added by design.

Match the collection band to the probe or reporter

Selection directions below; bands and sizes are example placeholders — actual values depend on the probe, medium and equipment.

01

Visible fluorescence

GFP, red fluorescent proteins

Information required
Exact variant, excitation and emission spectra, background conditions
Band and blocking priorities
e.g. 470/40 nm excitation + 525/50 nm emission; check OD ≥6 at the emission side (confirm against measured spectra)
Mounting
e.g. Ø25.0 × 4.0 mm round or 25.4 × 25.4 mm square
02

Near-infrared fluorescence

Cy5.5, Cy7, IRDye series, ICG

Information required
Exact probe, medium, source and target collection range
Band and blocking priorities
e.g. ICG-type: 748/33 nm excitation + 780 nm longpass (confirm against the measured spectrum in medium)
Mounting
e.g. Ø25.0 × 4.0 mm with adapter ring per mount
03

Bioluminescence

Firefly luciferase and other reporters

Information required
Enzyme/substrate pair, real emission spectrum and collection target
Band and blocking priorities
e.g. 560–700 nm broad-band high transmission or 600 nm longpass, photon flux first
Mounting
e.g. Ø25.0 × 4.0 mm or 50.8 × 50.8 mm large aperture
04

Multi-probe imaging

Combinations of fluorescent or luminescent reporters

Information required
Individual spectra, mixed signal and unmixing plan
Band and blocking priorities
e.g. four channels 500/40, 575/40, 630/50, 700/50 nm (adjust to unmixing needs)
Mounting
e.g. Ø25.0 × 3.0 mm thin discs for filter wheels
05

NIR-II / SWIR

Related research probes

Information required
Measured emission range, lens transmission and detector response
Band and blocking priorities
e.g. 1000 nm longpass or 1300/100 nm bandpass (set by the whole-chain transmission)
Mounting
e.g. fused silica substrate Ø25.0 × 3.3 mm

Probes of the same family, different protein variants or different substrate combinations can have different spectra. A name alone does not define the passband.

From single filters to complete multi-band sets

Grouped by optical function; excitation, emission and beam-splitting elements are selected together.

01

Excitation bandpass filter

Selects the fluorescence excitation band

Typical use
Source match, transmission and leakage into the detection band
02

Emission bandpass filter

Defines the collected target-signal range

Typical use
Fluorescence yield, background and adjacent-channel response
03

Longpass filter

Collects signal beyond the edge

Typical use
Edge position, excitation rejection and usable detector range
04

Dichroic mirror

Combines or separates different wavelength paths

Typical use
Transmission/reflection direction, working angle and polarization
05

Multi-band filter wheel set

Sequential multi-channel image capture

Typical use
Spectral coverage, size, thickness and response consistency
06

NIR-II / SWIR filter elements

For the corresponding research imaging bands

Typical use
Substrate, coating and transmission of the complete system

A multi-band filter wheel set means several filters forming one acquisition scheme; whether a single multi-bandpass design applies has to be assessed against the signal separation method.

How to choose filters for low-light imaging

  1. 01

    Collection band and usable signal

    Choose the band from real probe emission, tissue transmission and camera response — not only from the emission peak measured in solution.

  2. 02

    Balancing bandwidth against background

    A wider band usually collects more signal but may also admit more background. A narrower band helps separate some spectral components but reduces photon flux.

  3. 03

    Excitation and emission working together

    Check excitation leakage in the detection band and emission blocking of the excitation light; do not judge a single filter by its peak value alone.

  4. 04

    Autofluorescence and multispectral separation

    A suitable band reduces part of the background; where target and background spectra overlap, controls, multi-band acquisition and algorithmic processing are also needed.

  5. 05

    Large field and wide aperture

    Incidence angle varies across the field. Provide filter position, lens parameters and beam cone angle, then check band shift and image response uniformity.

  6. 06

    Component background and mounting

    Assess possible background, reflection or vignetting from substrate, coating, adhesive and housing under the real illumination and collection conditions.

Custom manufacturing capability

These are the ranges we normally produce. Requirements beyond them can be evaluated from drawings; final values are confirmed by sample and datasheet.

Specification Range we can produce
Excitation wavelengths 405, 488, 561, 638, 760, 808 nm
Emission range Visible to NIR-II (1000-1700 nm)
Multiband filters Simultaneous imaging across several fluorescence channels
Blocking depth OD5-OD6 for strong background suppression
Transmission T >70% for high collection efficiency on weak signals
Large aperture φ50-φ100 mm to match large-field cameras
Background control Reduces excitation scatter; tissue autofluorescence overlapping the target needs probe and spectral handling
T % nm 444448 452456 FWHM CWL Schematic, not measured data; CWL and FWHM definitions must be stated in the specification
Overlaid excitation and emission spectra: schematic and measured curves labelled separately
OD nm 65 43 2 450520 570620 OD6 in blocking region Passband (transmitting) Schematic; OD must be stated with the wavelength range
Passband transmission and blocking curves: test conditions and incidence angle stated
T % nm 400500 600700 450 nm 492 nm 570 nm 620 nm Schematic; each channel passband follows the assay method and instrument requirements
Multi-channel spectral coverage: channel passbands and their neighbours

Recommended: overlaid excitation and emission spectra, passband transmission and blocking curves, multi-channel coverage charts, dimensional drawings and filter-wheel mounting illustrations, plus environmental and background test data with traceable evidence. Charts distinguish schematic, typical, guaranteed and measured values.

Near-infrared in vivo imaging must match the whole optical chain

Near-infrared probes are used in small-animal in vivo optical imaging. Selection should combine tissue absorption and scattering, probe brightness, light source and detector response — a longer wavelength alone does not define performance.

Stage What to check
Probe and light source Confirm real excitation efficiency and emission range.
Filters and lens Confirm transmission in the target band and excitation rejection.
Detector and acquisition Confirm effective response, noise and exposure conditions.

NIR-II / SWIR proposals list concrete working ranges rather than a band name in place of technical specifications.

For in vivo imaging instruments and research platforms

Filters and beam splitters configured for the imaging mode, probe and instrument layout.

Small-animal fluorescence imaging system

Small-animal fluorescence imaging system

Excitation and emission filters set around the probe spectrum and illumination layout.

Small-animal bioluminescence imaging system

Small-animal bioluminescence imaging system

Detection path configured for broad-band or band-resolved collection.

Multispectral in vivo imaging platform

Multispectral in vivo imaging platform

Multi-channel acquisition supplies the information needed to separate target from background.

Near-infrared probe research platform

Near-infrared probe research platform

Bands matched across probe, lens and camera.

Drug distribution and cell-tracking instruments

Drug distribution and cell-tracking instruments

Optical scheme set by the labelling method and experimental goal; filter performance is not presented as an experimental conclusion.

From probe spectrum to system verification

Requirements → spectral & mechanical assessment → sample set → imaging verification → specification release

  1. 1

    Requirements

    Collect imaging mode, probe spectra, light source, camera, lens and mounting conditions.

  2. 2

    Assessment

    Confirm passbands, blocking ranges, working angles and multi-channel combinations.

  3. 3

    Sample set

    Prepare samples according to the assessment.

  4. 4

    Imaging verification

    Prefer standard fluorescent materials, optical phantoms or suitable reference samples; check background, excitation leakage, field uniformity and channel cross-response. Multispectral systems further verify calibration and unmixing.

  5. 5

    Specification release

    Define spectral and mechanical specs, lot consistency and delivered documentation.