NDIR Gas Analyzer Filters

Matched to the gas absorption band, with measurement and reference channels

For non-dispersive infrared analyzers, gas sensors and multi-component detection modules. Working from the target gas, the concentration range, the optical path length and the detector response, we design IR bandpass filters and reference-channel filters for selective gas detection and optical module integration.

  • Absorption matching
  • Measurement + reference
  • Out-of-band blocking
  • Multi-gas channels
4.26 μm Common CO2 measurement band
Dual channel Measurement and reference as a set
Blocking Set by source and detector response
IR source, gas cell and dual-channel detector filter set
Channel structure and element positions are schematic and vary between models

What is an NDIR gas analyzer filter?

NDIR stands for non-dispersive infrared. The principle is straightforward: a target gas absorbs a specific infrared band, so measuring how much light is lost across the gas cell gives the concentration.

"Non-dispersive" means the system does not spread the spectrum with a grating or prism and scan it point by point. In the usual structure an infrared filter selects the band that matches the absorption feature of the gas, and the detector receives the integrated radiation within that band.

An NDIR filter is normally an infrared bandpass element: it passes the target band and suppresses radiation elsewhere in a defined range. It can be a separate component in the optical path, or integrated into the window of a thermopile, pyroelectric or suitable photon detector.

Its job is not only to "pick one wavelength". It also sets how wide a band is covered, limits non-target signal, and together with source, gas cell and detector forms the response the instrument actually measures.

To be clear: a filter improves spectral selectivity, but it does not by itself determine detection limit, concentration range or measurement accuracy. Those are validated in the complete system.

Working principle: from IR absorption to gas concentration

The filter decides which slice of the infrared takes part; the concentration is worked back from how much of it was absorbed.

  1. 01

    Infrared enters the gas cell

    Radiation from the source passes through the gas under test. The target gas absorbs part of the energy in its characteristic band, so transmission in that band drops.

  2. 02

    The measurement filter selects the band

    The measurement channel filter covers the usable absorption region of the target gas. As the concentration changes, the signal reaching the detector changes with it.

  3. 03

    The reference channel tracks common drift

    A common two-wavelength design adds a second filter in a band where the target gas absorbs weakly and which suits the actual gas mixture. Comparing the two signals helps compensate source intensity and part of the shared optical drift.

  4. 04

    Calibration and ambient data give the concentration

    The system puts the measurement signal, the reference signal and the applicable temperature and pressure into the calibration model to obtain the concentration.

Source and gas cell Channel selection and detection IR source mid-IR broadband continuum Gas cell target gas absorbs path length L Measurement absorption band Reference weak absorption Detector 1 signal Detector 2 reference Signal processing ch ratio Signal ratio → calibration model (with T / P) → gas concentration ① Both channels share the same optics and detector, which is what makes comparison meaningful
IR source → gas cell → measurement filter / reference filter → dual-channel detector → signal processing and compensation → gas concentration The dual-channel function can be built in different ways; the schematic does not fix the channel count, the layout or the detector type.

The two filters are not "one accurate, one decorative": the reference channel only compensates when it shares the same drift sources as the measurement channel.

Measurement and reference channels: how the two filters work together

One channel sees the absorption; the other tells you whether the change came from the gas at all.

The difference between the measurement and the reference filter is not in the coating process but in the job each one does. The table compares them on band choice, purpose, design focus and verification.

Item Measurement channel filter Reference channel filter
Band choice Covers the usable absorption region of the target gas A usable region where the target gas absorbs weakly
Main purpose Detects the signal change caused by gas absorption Helps identify common drift of source and part of the optical path
Design focus Absorption strength, range, interfering gases, signal level Gas background, signal level, correlation with the measurement channel
Verification Concentration response and cross-interference Compensation effect and long-term drift

For CO2, a measurement channel near 4.26 μm with a reference channel near 3.9 μm is a common combination. It is a typical design direction, not a universal configuration for every gas and mixture.

A reference channel does not remove every error. Source drift differs between bands, window contamination, filter thermal drift and interference absorption may not be common to both channels, so the compensation still has to be validated on the real system.

Typical bands and selection

The bands below match common gas absorption features and serve as a starting point; bandwidth, transmission and blocking still follow the instrument conditions.

Filter type Nominal wavelength Application Selection note
CO2 measurement bandpass 4260 nm / 4.26 μm Carbon dioxide measurement Designed around the absorption region; bandwidth set with the range and cell length
CO2 reference bandpass 3900 nm / 3.90 μm CO2 reference channel Used with the measurement channel; assess background gas and the stability of both signals
CH4 measurement bandpass 3350 nm / 3.35 μm Methane measurement Passband set with the methane spectrum and cross-interference from other hydrocarbons
Automotive exhaust bandpass 3470 nm / 3.47 μm Exhaust gas channels "Automotive exhaust" is an application class; the target species and calibration still have to be defined
Alcohol detection bandpass 3570 nm and 5640 nm (two candidates) Alcohol detection channels Listed as two candidate bands; the target alcohol, channel role and interference conditions must be defined
CO measurement bandpass 4650 nm / 4.65 μm Carbon monoxide measurement Passband refined from the actual spectrum, range and source / detector response
CO reference bandpass 5050 nm / 5.05 μm CO reference channel Reference band suitability assessed against the actual gas mixture
SO2 measurement bandpass 7350 nm / 7.35 μm Sulphur dioxide measurement Designed with water vapour and other background species, substrate transmission and detector response

The nominal wavelengths and application mapping above are given as product selection directions; they do not mean every specification has been fabricated or application-validated. 3570 nm and 5640 nm are listed as two candidate filter bands, not as a single dual-band element.

Beyond the nominal wavelength, a complete NDIR filter specification includes centre wavelength tolerance, FWHM, passband transmission, blocking range, working incidence angle, operating temperature and outline dimensions. Measurement and reference channels are best assessed as a set against the instrument structure, with concentration response and cross-interference confirmed by actual gas testing.

Filter passband Target absorption Interfering absorption Relative scale Blocking region set by source and detector Passband FWHM Interference inside the passband → higher out-of-band OD does not help 3.5 4.26 5.0 6.0 7.0 8.0 Wavelength (μm) ※ Design schematic, not measured data; axis is illustrative and widths are not to scale
Filter passband, target gas absorption and interfering gas absorption (design schematic, not measured data)

Product options: choosing the structure by channel position

The four structures differ in where they sit and what they solve; real projects often combine several of them.

Option A

Single-gas measurement bandpass filter

A transmission window designed around the target absorption region for a single-component channel. Design has to balance absorption contrast, useful flux, concentration range and interference rejection. The strongest absorption region is not always best for the whole range: at high concentration or long path length, signal saturation has to be watched.

Design focus
Centre position, bandwidth, transmission, out-of-band blocking.
Option B

Measurement and reference filter pair

Measurement and reference filters designed as a set, used with a dual-channel detector or another two-channel structure. The two transmissions do not have to be equal; what matters is that, with the source and detector, both signals sit in a suitable dynamic range and that the channel ratio stays stable.

Design focus
Signal level in both channels, thermal behaviour, channel consistency, marking.
Option C

Multi-gas filter set

Measurement channels for several target gases, with reference channels where needed. Several gases may respond in the same band, so the set has to be designed together with cross-interference testing, the calibration model and the compensation algorithm. More channels do not automatically mean every component is measured independently and accurately.

Design focus
Channel combination, overlapping absorption, background gas, set matching.
Option D

Detector package window

The filter function integrated into the detector window for single, dual or multi-channel packages. Outline, thickness, clear aperture, package process temperature, assembly stress and channel isolation all have to be confirmed together.

Design focus
Spectral performance and package compatibility.

The four options can be layered: one analyzer may combine a package window, a measurement / reference pair and multi-channel expansion, so each position should be confirmed separately.

Specifications and customisation notes

The table lists the parameters to confirm item by item; fabrication ranges and delivery figures are confirmed against validated capability.

Parameter Customisation Explanation
Target gas Single gas or multi-component List the interfering gases that may coexist
Concentration and path Range, expected detection need and effective cell length Sets absorption strength and the span of the signal change
Centre wavelength Target position and permitted deviation Determined from the absorption feature inside the passband
FWHM Passband width and tolerance Not the same as a guaranteed band at a stated transmission
Passband transmission Peak, average or minimum State the definition and the wavelength interval
Out-of-band blocking Transmission limit or OD over a stated range Blocking range set by source and detector response
Passband shape Edges, flatness and permitted variation The whole curve affects the integrated absorption response
Reference channel Band, width and matching conditions No single reference wavelength is a universal standard
Incidence conditions Nominal angle, angular spread and polarisation Assessed from the beam leaving the actual cell
Temperature behaviour Operating range and spectral change with temperature Separate thermal drift from manufacturing tolerance
Substrate and thickness Chosen for IR transmission and process conditions Material absorption can limit the usable band
Outline and aperture Per mounting or package drawing Distinguish the outline from the guaranteed optical area
Environment Humidity, corrosive gas, contamination and cleaning Assessed with whether the filter touches the gas directly
Delivery data Spectra, dimensions, channel marking and batch records Test conditions and sampling method agreed

The blocking range of an NDIR filter has to cover the bands that actually contribute interference. Even far from the passband, a strong source and a detector that still responds can turn a small leak into a background signal, so checking only the immediate flanks of the passband is not enough.

clear aperture Single element outline vs clear aperture signal ref Dual-channel pair energy balance and isolation coated window Package window spectrum and package fit ※ Three forms by mounting position; dimensions, coated face and orientation per drawing
Three delivery forms: single element, dual-channel filter pair and detector package window (structure schematic; dimensions per drawing)
Short path L1 Long path L2 Signal short path long path long path saturates about here 0 25 50 75 100 Gas concentration c ※ Relationship schematic, not measured data; actual saturation depends on absorption, bandwidth and source output
Range, path length, bandwidth and signal: the same filter in a longer path saturates earlier (relationship schematic, not measured data)

Four questions worth settling before selection

These are the four items most often skipped at enquiry stage, and each one changes the final specification.

Q1

Narrower is not automatically better

A narrower passband helps avoid some interfering absorption, but it also reduces flux and makes the system more sensitive to wavelength error and angle. Bandwidth follows the absorption spectrum, the signal-to-noise ratio and the range.

Q2

The strongest absorption is not best for every range

Where absorption is excessive, the high-concentration end may leave only a very weak transmitted signal, and further concentration change becomes hard to resolve. Path length, band position or bandwidth can be adjusted instead.

Q3

Interference inside the passband cannot be blocked away

If an interfering gas absorbs within the normal passband, raising out-of-band OD does not remove it. The passband, multi-channel compensation or another system approach has to be reconsidered.

Q4

Temperature and pressure affect the measurement

They change gas number density and line shape, while source, filter and detector may also shift with temperature. Filter thermal drift is only part of the instrument environmental response.

Applications and adaptation points

Monitoring indoor CO2 and analysing an industrial process ask for very different path length, range and long-term stability.

Application Typical task Filter design focus
Indoor air and ventilation CO2 concentration monitoring Signal efficiency, reference channel, long-term stability
Industrial process analysis CO2, CO, CH4 and other components Range, background gas, cross-interference
Biogas and energy gases Multi-component concentration High-concentration response, humidity, gas mixtures
Environmental and emission analysis Selected gas components Multi-channel adaptation, sample conditioning, compensation
Respiratory gas analysis CO2 and similar changes Measurement bandwidth, response speed, module flux
Miniature gas sensors Compact detection modules Package window, clear aperture, channel consistency

Response speed and accuracy in applications such as respiratory gas analysis have to be validated on the complete instrument; they cannot be inferred from filter parameters alone.

Custom process

Gas and range definition → absorption and interference assessment → spectral design → structure matching → sample validation → specification release

  1. 1

    Define the need

    Target gas, concentration range, path length and operating environment.

  2. 2

    Assess interference

    Coexisting species, water vapour and possible window contamination.

  3. 3

    Design the channels

    Measurement band, reference band, bandwidth and blocking range.

  4. 4

    Match the structure

    Detector type, mounting position, angle and package dimensions.

  5. 5

    Validate samples

    Spectra checked, then concentration response, temperature and cross-interference tests.

  6. 6

    Release the specification

    Drawings, acceptance conditions and batch consistency requirements.