ISO 9001 Certified Manufacturer 360° Factory Tour
90:10 Beam Splitter (VIS) OT-BS9010-VIS — OOTEE Optics
90:10 Beam Splitter (VIS) OT-BS9010-VIS
  • BrandOOTEE Optics
  • Lead TimeIn stock — ships within 3 working days (custom parts scheduled per drawing)
  • MOQMOQ 1 pc for standard items; tiered pricing for custom parts
  • PackingIndividual boxed with a spec card enclosed

90:10 Beam Splitter (VIS) Model No.OT-BS9010-VIS

400–700 nmUV350400450500550600650700750 400–700 nmUV400500600700
Drawn to scale from this part CWL and FWHM; UV and IR ranges shown as invisible

90:10 Beam Splitter (VIS); operating band 400-700nm; transmission 90%; reflectivity 10%; size 25.4×35.6×1.1mm; AOI 45°.

Key Specs at a Glance

Tell if it fits in three seconds
  • Passband 400-700nm
  • Transmission 90%
  • Reflectivity 10%
  • AOI 45°
  • Dimensions 25.4×35.6×1.1mm
  • Substrate 1.1mm
  • Request a quote
  • Tiered pricing
  • Sample pricing

Overview & Highlights

90:10 Beam Splitter (VIS) is a Beam Splitter engineered for dividing one beam into two paths, passband 400-700nm, ≥90% peak transmission, AOI 45°.

01

≥90% high transmission

In-band transmission of ≥90% delivers a stronger signal at the same exposure and cuts the required illumination power.

02

Ion-assisted deposition coating

Deposited by ion-assisted deposition (IAD) for a dense hard coating with low moisture uptake, minimal wavelength drift and good batch-to-batch repeatability.

Full Technical Specifications

Optical Performance

Passband 400–700nmCustom
Transmission 90%
Reflectivity 10%
* Other parameters not applicable to this part
  • CWL
  • CWL Tolerance
  • FWHM
  • FWHM Tolerance
  • Reflection Band
  • Cut-off Band
  • Fluorophore
  • T at CWL
  • Cut-off Rate
  • Blocking OD

Dimensions & Tolerance

Dimensions 25.4×35.6×1.1mmCustom
Dimension Tol. +0.0/-0.1mmCustom
* Other parameters not applicable to this part
  • Ring Thickness
  • Ring Thickness Tol.
  • Clear Aperture

Substrate & Surface

Substrate Thickness 1.1mmCustom
Surface Quality 60/40
Coating Process Ion-assisted deposition (IAD)Custom
* Other parameters not applicable to this part
  • Substrate Thickness Tol.

Operating Conditions

AOI 45°Custom
* Other parameters not applicable to this part
  • 工作温度
  • 存储温度

Note: standard-part measured values. Centre wavelength, outline dimensions and blocking depth can all be made to your drawing.

Spectral Curve

Spectral data in progress

No online curve data for this model yet — we are uploading it. The interactive chart appears automatically once the data is in.

Request the spectrum data

Need a different specification?

Every parameter can be customised; samples in 2-4 weeks with tiered production pricing.

  • Centre wavelength and bandwidth
  • Blocking depth OD
  • Substrate material and thickness
  • Outline dimensions and aperture
  • Mounting style (ring / threaded / square)

Got a drawing and a spec sheet? Send them over — our engineering team will return a feasibility assessment and a quote.

Selection Guide

Recommended for

confocal and two-photon microscopy, interferometric and coherent detection, coaxial illumination, laser combining and power sampling

  • imaging and detection on the same optical path at once
  • combining two wavelengths into one beam
  • sampling a fixed fraction of a laser for power monitoring

Not recommended for

  • pure transmission or pure reflection — a filter or mirror is simpler
  • cases needing extreme ratio accuracy while the incidence angle swings widely — that calls for a custom design

How it differs from similar parts

covering 400-700nm; The split ratio is not a constant: it moves with incidence angle, polarisation and wavelength. Always quote the working angle, band and polarisation state together — a bare "50/50" will drift in a real layout, and non-polarising types deserve extra care at steep angles.

Applications

90:10 Beam Splitter divides one beam into reflected and transmitted paths at a set ratio, widely used for beam combining/splitting in confocal microscopy, interferometry, coaxial illumination and machine-vision systems.

Downloads

Product DrawingPendingDownload
Spectral Curve ChartPendingDownload
DatasheetPendingDownload

Documents are being added continuously; contact us if you need one right away.

FAQ

Which instruments is 90:10 Beam Splitter (VIS) used in?

Mainly confocal and two-photon microscopy, interferometric and coherent detection, coaxial illumination, laser combining and power sampling. Final suitability depends on your actual wavelength, bandwidth and blocking requirements — send us the instrument model or channel specs and we will confirm.

Can 90:10 Beam Splitter (VIS) be customised in wavelength, size or blocking depth?

Yes. Centre wavelength, bandwidth, blocking depth, substrate material, outline dimensions and mounting style (ring-mounted, threaded, square …) can all be made to your drawing. Samples usually take 2–4 weeks; production lead time depends on quantity.

What are the MOQ and lead time?

Standard items ship from stock with an MOQ of one piece; custom parts are scheduled after drawing approval, with MOQ and tiered pricing scaling down by batch size — see the quotation for exact figures.

How do I check whether 90:10 Beam Splitter (VIS) fits my channel?

Check three things: whether the working band matches your detection wavelength, whether the band overlaps adjacent channels, and whether the blocking depth meets your background suppression requirement. Send us those three and we will advise directly.

What care does this filter need?

Never touch the coating with bare hands. Clean with a lint-free cloth or swab slightly moistened with anhydrous ethanol, store in a dry clean place, and avoid concentrated stress on the coated surface during mounting.

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide