≥95% high transmission
In-band transmission of ≥95% delivers a stronger signal at the same exposure and cuts the required illumination power.
DM635nm PCR Dichroic Mirror; passband 650-700nm; transmission Tave≥95%; reflection band 450-630nm; reflectivity Rave≥95%; size 10mm×15mm; AOI 45°.
DM635nm PCR Dichroic Mirror | 10mm×15mm is a PCR Fluorescence Filter engineered for multi-channel detection in quantitative PCR, passband 650-700nm, ≥95% peak transmission, AOI 45°.
In-band transmission of ≥95% delivers a stronger signal at the same exposure and cuts the required illumination power.
Deposited by ion-assisted deposition (IAD) for a dense hard coating with low moisture uptake, minimal wavelength drift and good batch-to-batch repeatability.
| Passband | 650–700nmCustom |
|---|---|
| Reflection Band | 450–630nmCustom |
| Fluorophore | Atto 633 |
| Transmission | Tave≥95% |
| Reflectivity | Rave≥95% |
| Dimensions | 10mm×15mmCustom |
|---|---|
| Dimension Tol. | +0.0/-0.1mmCustom |
| Substrate Thickness | 1.0mmCustom |
|---|---|
| Substrate Thickness Tol. | ±0.1mm |
| Surface Quality | 80/50 |
| Coating Process | Ion-assisted deposition (IAD)Custom |
| AOI | 45°Custom |
|---|
Note: standard-part measured values. Centre wavelength, outline dimensions and blocking depth can all be made to your drawing.
No online curve data for this model yet — we are uploading it. The interactive chart appears automatically once the data is in.
Request the spectrum dataEvery parameter can be customised; samples in 2-4 weeks with tiered production pricing.
Got a drawing and a spec sheet? Send them over — our engineering team will return a feasibility assessment and a quote.
FAM / VIC / ROX / Cy5 channels of real-time qPCR and digital dPCR instruments
covering 650-700nm; PCR channels are densely spaced (often less than 40nm apart), so wavelength accuracy and edge steepness matter more than raw peak transmission.
DM635nm PCR Dichroic Mirror is aligned with the excitation/emission bands of FAM/HEX/ROX/Cy5 reporters, widely used in the excitation and detection channels of real-time qPCR instruments, providing deep crosross-channel blocking for accurate multi-channel Ct values.
Documents are being added continuously; contact us if you need one right away.
Mainly FAM / VIC / ROX / Cy5 channels of real-time qPCR and digital dPCR instruments. Final suitability depends on your actual wavelength, bandwidth and blocking requirements — send us the instrument model or channel specs and we will confirm.
Yes. Centre wavelength, bandwidth, blocking depth, substrate material, outline dimensions and mounting style (ring-mounted, threaded, square …) can all be made to your drawing. Samples usually take 2–4 weeks; production lead time depends on quantity.
Standard items ship from stock with an MOQ of one piece; custom parts are scheduled after drawing approval, with MOQ and tiered pricing scaling down by batch size — see the quotation for exact figures.
Check three things: whether the working band matches your detection wavelength, whether the band overlaps adjacent channels, and whether the blocking depth meets your background suppression requirement. Send us those three and we will advise directly.
Never touch the coating with bare hands. Clean with a lint-free cloth or swab slightly moistened with anhydrous ethanol, store in a dry clean place, and avoid concentrated stress on the coated surface during mounting.