ISO 9001 Certified Manufacturer 360° Factory Tour
DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] OT-DM650LP-6x9 — OOTEE Optics
DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] OT-DM650LP-6x9
  • BrandOOTEE Optics
  • Lead TimeIn stock — ships within 3 working days (custom parts scheduled per drawing)
  • MOQMOQ 1 pc for standard items; tiered pricing for custom parts
  • PackingIndividual boxed with a spec card enclosed

DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] Model No.OT-DM650LP-6x9

670–700 nm400450500550600650700750 670–700 nm400500600700
Drawn to scale from this part CWL and FWHM; UV and IR ranges shown as invisible

DM650nm PCR Dichroic Mirror; passband 670-700nm; transmission Tave≥95%; reflection band 450-645nm; reflectivity Rave≥95%; size 6mm×9mm; AOI 45°.

Key Specs at a Glance

Tell if it fits in three seconds
  • Passband 670-700nm
  • Reflection Band 450-645nm
  • Fluorophore CY5/Qusar 670
  • Transmission Tave≥95%
  • Reflectivity Rave≥95%
  • AOI 45°
  • Request a quote
  • Tiered pricing
  • Sample pricing

Overview & Highlights

DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] is a PCR Fluorescence Filter engineered for multi-channel detection in quantitative PCR, passband 670-700nm, ≥95% peak transmission, AOI 45°.

01

≥95% high transmission

In-band transmission of ≥95% delivers a stronger signal at the same exposure and cuts the required illumination power.

02

Ion-assisted deposition coating

Deposited by ion-assisted deposition (IAD) for a dense hard coating with low moisture uptake, minimal wavelength drift and good batch-to-batch repeatability.

Full Technical Specifications

Optical Performance

Passband 670–700nmCustom
Reflection Band 450–645nmCustom
Fluorophore CY5/Qusar 670
Transmission Tave≥95%
Reflectivity Rave≥95%
* Other parameters not applicable to this part
  • CWL
  • CWL Tolerance
  • FWHM
  • FWHM Tolerance
  • Cut-off Band
  • T at CWL
  • Cut-off Rate
  • Blocking OD

Dimensions & Tolerance

Dimensions 6mm×9mmCustom
Dimension Tol. +0.0/-0.1mmCustom
* Other parameters not applicable to this part
  • Ring Thickness
  • Ring Thickness Tol.
  • Clear Aperture

Substrate & Surface

Substrate Thickness 1.0mmCustom
Substrate Thickness Tol. ±0.1mm
Surface Quality 80/50
Coating Process Ion-assisted deposition (IAD)Custom

Operating Conditions

AOI 45°Custom
* Other parameters not applicable to this part
  • 工作温度
  • 存储温度

Note: standard-part measured values. Centre wavelength, outline dimensions and blocking depth can all be made to your drawing.

Spectral Curve

Spectral data in progress

No online curve data for this model yet — we are uploading it. The interactive chart appears automatically once the data is in.

Request the spectrum data

Need a different specification?

Every parameter can be customised; samples in 2-4 weeks with tiered production pricing.

  • Centre wavelength and bandwidth
  • Blocking depth OD
  • Substrate material and thickness
  • Outline dimensions and aperture
  • Mounting style (ring / threaded / square)

Got a drawing and a spec sheet? Send them over — our engineering team will return a feasibility assessment and a quote.

Selection Guide

Recommended for

FAM / VIC / ROX / Cy5 channels of real-time qPCR and digital dPCR instruments

  • systems with several simultaneous channels where cross-talk must stay very low
  • replacement or spare sourcing against OEM channel specifications

Not recommended for

  • single-channel work where cross-talk is less critical — the cost is unnecessary
  • plain non-fluorescence blocking

How it differs from similar parts

covering 670-700nm; PCR channels are densely spaced (often less than 40nm apart), so wavelength accuracy and edge steepness matter more than raw peak transmission.

Applications

DM650nm PCR Dichroic Mirror is aligned with the excitation/emission bands of FAM/HEX/ROX/Cy5 reporters, widely used in the excitation and detection channels of real-time qPCR instruments, providing deep crosross-channel blocking for accurate multi-channel Ct values.

Downloads

Product DrawingPendingDownload
Spectral Curve ChartPendingDownload
DatasheetPendingDownload

Documents are being added continuously; contact us if you need one right away.

FAQ

Which instruments is DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] used in?

Mainly FAM / VIC / ROX / Cy5 channels of real-time qPCR and digital dPCR instruments. Final suitability depends on your actual wavelength, bandwidth and blocking requirements — send us the instrument model or channel specs and we will confirm.

Can DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] be customised in wavelength, size or blocking depth?

Yes. Centre wavelength, bandwidth, blocking depth, substrate material, outline dimensions and mounting style (ring-mounted, threaded, square …) can all be made to your drawing. Samples usually take 2–4 weeks; production lead time depends on quantity.

What are the MOQ and lead time?

Standard items ship from stock with an MOQ of one piece; custom parts are scheduled after drawing approval, with MOQ and tiered pricing scaling down by batch size — see the quotation for exact figures.

How do I check whether DM650nm PCR Dichroic Mirror | 6mm×9mm | TTave≥95% [OT-DM650LP-6x9] fits my channel?

Check three things: whether the working band matches your detection wavelength, whether the band overlaps adjacent channels, and whether the blocking depth meets your background suppression requirement. Send us those three and we will advise directly.

What care does this filter need?

Never touch the coating with bare hands. Clean with a lint-free cloth or swab slightly moistened with anhydrous ethanol, store in a dry clean place, and avoid concentrated stress on the coated surface during mounting.

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide