ISO 9001 Certified Manufacturer 360° Factory Tour
UV Multi-Band Filter OT-MB-UV — OOTEE Optics
UV Multi-Band Filter OT-MB-UV
  • BrandOOTEE Optics
  • Lead TimeIn stock — ships within 3 working days (custom parts scheduled per drawing)
  • MOQMOQ 1 pc for standard items; tiered pricing for custom parts
  • PackingIndividual boxed with a spec card enclosed

UV Multi-Band Filter Model No.OT-MB-UV

325–355 nmUV350400450500550600650700750340 nmFWHM 25 nm 325–355 nmUV400500600700340 nmFWHM 25 nm
Drawn to scale from this part CWL and FWHM; UV and IR ranges shown as invisible

UV Multi-Band Filter; CWL 340/380/440nm; FWHM 25/30/35nm; transmission >90%; blocking OD5; size Ø25.4mm; AOI 0°.

Key Specs at a Glance

Tell if it fits in three seconds
  • CWL 340/380/440nm
  • Passband 325-355nm 365-395nm 420-460nm
  • Cut-off Band 200-1100nm
  • FWHM 25/30/35nm
  • Transmission >90%
  • Blocking OD OD5
  • Request a quote
  • Tiered pricing
  • Sample pricing

Overview & Highlights

UV Multi-Band Filter is a Multiband Filter engineered for extracting several bands with one filter, a 340nm centre wavelength, a 25nm bandwidth, ≥90% peak transmission, OD5 out-of-band blocking, AOI 0°.

01

OD5 deep blocking

Out-of-band blocking reaches OD5 (OD5), suppressing stray light and improving the signal-to-noise ratio.

02

≥90% high transmission

In-band transmission of ≥90% delivers a stronger signal at the same exposure and cuts the required illumination power.

03

Ion-assisted deposition coating

Deposited by ion-assisted deposition (IAD) for a dense hard coating with low moisture uptake, minimal wavelength drift and good batch-to-batch repeatability.

Full Technical Specifications

Optical Performance

CWL 340/380/440nmCustom
FWHM 25/30/35nmCustom
Passband 325–355nm 365–395nm 420–460nmCustom
Cut-off Band 200–1100nmCustom
Transmission >90%
Blocking OD OD5Custom
* Other parameters not applicable to this part
  • CWL Tolerance
  • FWHM Tolerance
  • Reflection Band
  • Fluorophore
  • Reflectivity
  • T at CWL
  • Cut-off Rate

Dimensions & Tolerance

Dimensions Φ25.4mmCustom
Dimension Tol. +0.0/-0.1mmCustom
* Other parameters not applicable to this part
  • Ring Thickness
  • Ring Thickness Tol.
  • Clear Aperture

Substrate & Surface

Substrate Thickness 1.1mmCustom
Surface Quality 60/40
Coating Process Ion-assisted deposition (IAD)Custom
* Other parameters not applicable to this part
  • Substrate Thickness Tol.

Operating Conditions

AOI 0°Custom
* Other parameters not applicable to this part
  • 工作温度
  • 存储温度

Note: standard-part measured values. Centre wavelength, outline dimensions and blocking depth can all be made to your drawing.

Spectral Curve

Spectral data in progress

No online curve data for this model yet — we are uploading it. The interactive chart appears automatically once the data is in.

Request the spectrum data

Need a different specification?

Every parameter can be customised; samples in 2-4 weeks with tiered production pricing.

  • Centre wavelength and bandwidth
  • Blocking depth OD
  • Substrate material and thickness
  • Outline dimensions and aperture
  • Mounting style (ring / threaded / square)

Got a drawing and a spec sheet? Send them over — our engineering team will return a feasibility assessment and a quote.

Selection Guide

Recommended for

multi-label fluorescence imaging, multiplex flow cytometry, multi-line laser systems, food and produce sorting

  • collecting several fluorescence channels in one camera exposure
  • co-axial multi-line detection where a compact path without splitters matters
  • channel spacings too tight to build from stacked single-band filters

Not recommended for

  • detecting a single band only — one bandpass is more economical
  • channels needing independent exposure and gain — split the paths instead

How it differs from similar parts

with a 340nm centre wavelength; The hard part of a multiband filter is not peak transmission but isolation between bands: high pass inside each band and deep blocking in between pull against each other on one substrate. Quote the centre wavelength, bandwidth and inter-band OD of every channel together.

Applications

UV Multi-Band Filter opens multiple passbands on a single substrate for simultaneous imaging of DAPI/FITC/TRITC/Cy5 fluorophores, saving beam-splitting elements in multiband fluorescence imaging and coaxial detection systems.

Downloads

Product DrawingPendingDownload
Spectral Curve ChartPendingDownload
DatasheetPendingDownload

Documents are being added continuously; contact us if you need one right away.

FAQ

Which instruments is UV Multi-Band Filter used in?

Mainly multi-label fluorescence imaging, multiplex flow cytometry, multi-line laser systems, food and produce sorting. Final suitability depends on your actual wavelength, bandwidth and blocking requirements — send us the instrument model or channel specs and we will confirm.

Can UV Multi-Band Filter be customised in wavelength, size or blocking depth?

Yes. Centre wavelength, bandwidth, blocking depth, substrate material, outline dimensions and mounting style (ring-mounted, threaded, square …) can all be made to your drawing. Samples usually take 2–4 weeks; production lead time depends on quantity.

What are the MOQ and lead time?

Standard items ship from stock with an MOQ of one piece; custom parts are scheduled after drawing approval, with MOQ and tiered pricing scaling down by batch size — see the quotation for exact figures.

How do I check whether UV Multi-Band Filter fits my channel?

Check three things: whether the 340nm centre wavelength matches your detection wavelength, whether the band overlaps adjacent channels, and whether the OD5 blocking meets your background suppression requirement. Send us those three and we will advise directly.

What care does this filter need?

Never touch the coating with bare hands. Clean with a lint-free cloth or swab slightly moistened with anhydrous ethanol, store in a dry clean place, and avoid concentrated stress on the coated surface during mounting.

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide