Earth observation | Multispectral payloads | Spectral customisation
Spectral selection and multi-channel imaging for Earth observation payloads
Remote sensing satellite filters provide band selection, channel separation and rejection of unwanted light in Earth observation optical payloads. Working with the imaging optics and detectors, they capture radiance from the surface and atmosphere across different spectral ranges. For visible, near-infrared, short-wave infrared and thermal infrared requirements, bandpass filters, dichroic elements, multi-zone filter arrays and spectral cut-off components can be evaluated against the payload architecture to support agricultural monitoring, ecological survey, water-body identification, geological analysis and land surface temperature observation.

A remote sensing satellite filter is a spectral control element installed in a satellite optical payload. By selectively transmitting, reflecting or absorbing different wavelengths, it lets the detector receive light mainly within the specified band.
Surface features do not share the same spectral signature. Vegetation, for example, reflects differently in the red and near-infrared; moisture affects the response of some short-wave infrared bands; and thermal emission from the surface itself supports temperature-related observation. Capturing this information in separate channels provides a basis for feature classification and parameter retrieval.
In a remote sensing system, the filter mainly performs three tasks:
Determining which wavelength range each channel receives.
Reducing signal bleed from adjacent bands or other spectral regions.
Lowering the impact of out-of-band leakage on radiometric measurement and weak-signal detection.
For example, one multispectral instrument uses separate visible / near-infrared and short-wave infrared focal planes, with a stripe filter structure in front of the detectors to select the bands.
Choose the filter type by payload architecture; first clarify its spectral function, application direction and selection focus.
| Filter type | Technical description | Application direction |
|---|---|---|
| Single-band bandpass filter | Transmits within a specified band and suppresses unwanted light on both sides of the passband | Multispectral cameras, independent detection channels |
| Narrowband filter | Selects a narrower spectral region to highlight specific reflection, absorption or emission features | Feature-band observation, selected atmospheric and ecological remote sensing systems |
| Multi-zone / stripe filter array | Places different passbands in different spatial zones, matched to detector rows or imaging areas | Pushbroom multispectral payloads, focal-plane integration |
| Linear variable filter (LVF) | The passband centre wavelength changes gradually along one spatial direction | Selected spectral imaging architectures, spectral selection or stray-light suppression |
| Dichroic beamsplitter | Transmits or reflects different bands into separate optical paths | Visible, NIR and SWIR channel-splitting designs |
| Longpass / shortpass filter | Retains the spectrum on one side of a cut edge | Band boundary control, spectrometer order sorting |
| Infrared bandpass filter | Selects the passband according to the infrared detector and observation window | SWIR and thermal infrared payloads |
| Broadband cut-off component | Suppresses other sensitive bands while retaining the useful signal | Spectral clean-up in front of the detector, auxiliary cut-off |
Four common filter structures (illustrative forms, not measured data)




A multi-zone filter is not a multi-band filter: the former varies by position, the latter passes several bands at one position and does not create separate band images.
The nominal bands from the published Sentinel-2 mission design are used below as a multispectral selection reference. The bandwidths are mission design reference values, not the measured response of any particular satellite, nor acceptance criteria for our filters.
| Band | Nominal centre wavelength | Nominal bandwidth | Main application |
|---|---|---|---|
| B1 Coastal / aerosol | 443 nm | 20 nm | Aerosol information and atmospheric correction support |
| B2 Blue | 490 nm | 65 nm | Visible imaging, water and surface information |
| B3 Green | 560 nm | 35 nm | Vegetation green reflectance, water and feature classification |
| B4 Red | 665 nm | 30 nm | Vegetation absorption feature, vegetation index with NIR |
| B5 Red edge | 705 nm | 15 nm | Vegetation red-edge feature analysis |
| B6 Red edge | 740 nm | 15 nm | Vegetation state and canopy information |
| B7 Near red edge | 783 nm | 20 nm | Transition toward the high NIR reflectance region |
| B8 Near infrared | 842 nm | 115 nm | Vegetation cover, land-water separation, vegetation indices |
| B8A Narrow NIR | 865 nm | 20 nm | Vegetation analysis with a narrower NIR channel |
| B9 Water vapour | 945 nm | 20 nm | Atmospheric water vapour estimation and correction |
| B10 Cirrus | 1375 nm | 30 nm | Thin cirrus identification and cloud screening |
| B11 SWIR | 1610 nm | 90 nm | Vegetation water stress, snow/ice and cloud identification |
| B12 SWIR | 2190 nm | 180 nm | Surface and vegetation moisture, snow/ice and feature separation |
The definitions below set out the meaning and limits of each parameter, so that a single filter curve is not mistaken for the whole-instrument spectral response.
| Parameter | Detailed definition | Selection / acceptance note |
|---|---|---|
| Centre wavelength & spectral response | Centre wavelength describes the position of the passband on the spectral axis, but its calculation method must be stated, e.g. the midpoint of the half-maximum points or a transmittance-weighted value. In remote sensing, what is used for data interpretation is the whole-channel spectral response, which combines filter transmittance, other optical element responses and detector sensitivity | A single filter curve cannot replace the whole-instrument spectral response curve |
| FWHM & spectral resolution | FWHM is the wavelength interval between the two half-peak transmittance points and describes the width of a bandpass filter. Filter bandwidth, channel sampling interval and instrument spectral resolution are different concepts | For hyperspectral systems the final resolving power also depends on the slit, disperser, aberrations and detector sampling; filter bandwidth must not be treated as instrument spectral resolution |
| In-band transmittance | In-band transmittance is the proportion of useful spectrum passing the filter, and it should be stated whether a peak, average or minimum value is used | Remote sensing targets can be dim and integration time is limited by scan rate; the design must balance in-band throughput, spectral selectivity and out-of-band rejection, not simply pursue a narrower band |
| Out-of-band blocking & integrated leak | Blocking depth is usually expressed as optical density OD: OD = -log10(T), where T is the transmittance fraction; OD4 corresponds to 0.01% transmittance | Beyond the blocking depth at one wavelength, the energy accumulated over the whole unwanted band reaching the detector also matters; a very wide out-of-band region can affect a weak-signal channel even if leakage at each point is low |
| Spatial uniformity | Spatial uniformity describes whether centre wavelength, bandwidth and transmittance are consistent across the filter; long stripe filters and area-array imaging systems need multi-point measurement over the actual effective area | For an LVF, wavelength changing with position is a design feature; the focus is the variation law, local bandwidth and position-wavelength calibration accuracy, not a demand that the whole plate share one centre wavelength |
| Angle of incidence & polarisation | The passband of an interference filter shifts with angle of incidence, and at oblique incidence different polarisation states may respond differently | A remote sensing payload should define test conditions from the real beam cone angle, chief-ray angle and field position; a normal-incidence curve alone may not describe real imaging performance |
| Temperature stability | Temperature change can alter the optical thickness of the coating and the substrate dimensions, shifting the passband position or transmittance | Specifications should distinguish operating temperature, storage temperature and the allowed change before and after environmental testing; a room-temperature curve cannot replace measurement under the real operating conditions of a cryogenic infrared payload |
| Array boundaries & crosstalk | A multi-zone filter must control zone dimensions, boundary transition width, leakage between adjacent channels and alignment error to the detector | Channel crosstalk may come not only from the filter but also from assembly gaps, scattering, detector structure and the imaging path, and should be verified at assembly or instrument level |
Blocking depth must be specified together with the blocking band, edge transition and test conditions. Stating "OD4" alone cannot show whether leakage exists across the whole camera response range.
Environmental requirements for remote sensing satellite filters depend on the specific mission. Orbit, mounting position, shielding and mission lifetime all change the verification items and test levels.
| Verification item | Main focus | Suggested records |
|---|---|---|
| Thermal vacuum & temperature cycling | Spectral, coating and assembly stability under vacuum and temperature change | Test conditions, process records and before/after performance comparison |
| Vibration & shock | Structural integrity, fixation reliability and position change under launch loads | Assembly-level test records and re-measurement results |
| Radiation assessment | Effect of mission-relevant radiation on substrate, coating and spectrum | Radiation type, dose conditions and performance change |
| Contamination & outgassing control | Effect of adhesives, coatings, packaging and nearby materials on optical surfaces | Material list, outgassing data and cleaning control records |
| Spectral stability | Change in centre wavelength, passband and blocking performance | Spectral data before and after environmental testing |
| Traceability | Substrate, coating, fabrication, assembly and inspection batches | Unique ID, process and inspection records |
The list below is a customisation requirements checklist, intended as an input for project discussion; the actual supply scope is confirmed after process evaluation.
| Customisation direction | Points to confirm |
|---|---|
| Spectral design | Number of channels, centre wavelengths, bandwidths, passband shape and spectral tolerances |
| Blocking design | Blocking range, blocking depth, transition zone and integrated leakage requirements |
| Substrate & coating | Operating band, temperature, transmission needs, coating stress and environmental conditions |
| Outline machining | Round, rectangular or stripe dimensions, thickness, chamfer and effective clear aperture |
| Zone structure | Zone dimensions, arrangement, boundary width, alignment datum and channel mapping |
| Optical path fit | AOI range, beam cone angle, polarisation and mounting orientation |
| Assembly design | Bare filter or assembly form, fixing method, thermal expansion match and stress control |
| Optical quality | Surface quality, parallelism, transmitted wavefront and scattering requirements |
| Inspection deliverables | Multi-point spectra, dimensions, environmental testing and traceability records |
Mission & payload requirements > Spectral and structural evaluation > Sample fabrication > Optical inspection > Payload fit verification > Project-based environmental testing > Specification sign-off and delivery
Define observation targets, band needs, detector type and orbital environment.
Assess candidate schemes against target spectra, channel count and payload architecture.
Complete substrate, coating, zone patterning and outline machining.
Measure multi-point spectra, passband, blocking and in-aperture uniformity.
Verify AOI, alignment and channel crosstalk in the assembly or instrument optical path.
Arrange thermal vacuum, vibration, radiation and other tests per mission level.
Form drawings, acceptance conditions, inspection records and traceability data.
Choose which categories of cookies you allow. Essential cookies are always active because the site cannot run without them. Your choice is stored for 12 months and can be changed at any time from the footer.
Required for core functions such as language selection, security, and remembering your cookie choice. These cannot be turned off.
Would help us understand how visitors use the site so we can improve it. No analytics service is currently enabled on this website.
Would be used to measure campaigns and show relevant content. No advertising or remarketing service is currently enabled on this website.
This site currently sets no advertising, tracking or third-party cookies. Your consent choice is kept in your browser local storage, not in a cookie. See the Cookie Policy for details.