ISO 9001 Certified Manufacturer 360° Factory Tour

Industrial inspection · Spectral & intensity control

Machine Vision Optical Filters

Match the illumination band and make targets easier to detect

For industrial cameras, smart cameras, line-scan systems and inspection equipment: bandpass, long pass, IR-cut, polarizing and neutral density filter solutions matched to the light source wavelength, target material, ambient light and lens structure — supporting location, identification, measurement and defect detection.

  • Select the target illumination band and reduce part of the ambient light
  • Use spectral differences between materials to raise target-background contrast
  • Work with polarized illumination to reduce part of the surface glare
  • Control the light reaching the camera to suit exposure and inspection conditions

What is a machine vision filter?

A machine vision filter is an optical element installed at the illumination end, in front of the lens or inside the camera, used to shape the spectrum, polarization state or intensity of the light that forms the image.

An industrial camera simply records the light reaching the sensor; it cannot tell whether that light comes from the inspection source, factory lighting or surface reflections. By keeping the light that helps inspection and removing part of the unwanted light, filters make target features easier to separate.

The value usually lies in raising the distinguishability between target and background — not simply making the image brighter. Some tasks keep the light reflected by the target, while others work better with a darker target on a brighter background.

Source spectrum × Material reflection/emission × Filter transmission × Camera response

Knowing only "we use red light" or "we need ambient-light rejection" is not enough to specify a filter — the actual wavelength, source spectral width and imaging conditions must be confirmed.

Common filter types

Choose the filter type by inspection task first, then the detailed specifications.

Type Main role Typical applications
LED-matched bandpass filters Keep the illumination band, suppress part of the off-target light Location, OCR, contour and defect detection
Narrowband interference filters Select wavelengths within a narrow interval Laser-line extraction, structured light, selected NIR imaging
Long pass filters Transmit the usable band above the cut-on edge NIR imaging, some fluorescence detection
IR-cut filters Keep visible light, reduce near-IR response Color recognition, appearance and color inspection
Polarizing filters Select light by polarization state Glare control on glass, film, coating and packaging surfaces
Neutral density filters Reduce light intensity Exposure control, imaging of bright targets
Fluorescence filter sets Separate excitation from emission light Glue, coating, oil and fluorescence-label detection

Common LED-matched bandpass filter specifications

The table lists reference specifications for common selection directions. "Useful range" follows common industry practice — it is not the FWHM and must not be read as peak transmission across the whole interval. Actual supply capability and measured performance follow our verified manufacturing and test results and the datasheet.

Product direction Typical LED sources Useful range FWHM Peak transmission Surface quality
Near-UV bandpass (365 nm) 365 nm LED 335–385 nm 80 nm ≥85% 40/20
Blue bandpass (470 nm) 450 / 465 / 470 nm LED 425–495 nm 85 nm ≥90% 40/20
Green bandpass (525 nm) 520 / 525 / 530 nm LED 500–555 nm 80 nm ≥90% 40/20
Light-red bandpass (635 nm) 617 / 625 / 630 nm LED 615–645 nm 60 nm ≥90% 40/20
Deep-red bandpass (660 nm) 660 nm LED 640–680 nm 60 nm ≥90% 40/20
Near-IR bandpass (850 nm) 840 / 850 nm LED 820–910 nm 160 nm ≥90% 40/20
940 nm companion bandpass 940 nm LED 928–955 nm 55 nm ≥85% 40/20

The surface quality grades above apply to the common size conditions; grades for larger sizes must be confirmed per specification and must not be extended to all sizes unconditionally.

365 nm: for imaging that receives near-UV light. If 365 nm excitation with visible fluorescence detection is used, the camera side usually needs the matching emission filter — a 365 nm bandpass cannot simply be reused.

470 nm / 525 nm: combine with blue or green illumination for surface or contrast inspection; the actual effect depends on the material.

635 nm / 660 nm: verify the actual wavelength of the red source — not all red illumination is the same specification.

850 nm / 940 nm: confirm the camera near-IR response and whether an internal IR-cut filter is present.

Out-of-band blocking depth must be confirmed per wavelength range for each product direction; the whole bandpass family should not be uniformly labelled with a single OD grade (e.g. OD4 or OD5).

LED emission Filter transmission Filter passband Intensity ↑ Passband should cover source width and drift ambient (rejected) ambient (rejected) 300 400 500 600 700 Wavelength (nm) · illustrative, not a specific product ※ Design schematic, not measured data
The passband must cover the source spectral width and drift while rejecting ambient light on both sides (design schematic)

Narrowband filter in detail: an 850 nm / 10 nm example

Narrowband filters suit applications that need stronger spectral selectivity, but they must match the source spectral width and the actual angle of incidence. The industry-spec example below helps you understand the product parameter structure more clearly.

Parameter Example specification
Example type 850 nm hard-coated narrowband interference filter (unmounted, industry-spec example)
Center wavelength CWL 850 ±2 nm
FWHM 10 ±2 nm
Transmission ≥85% (minimum-transmission basis)
Average blocking OD OD ≥4.0
Blocking range Specified stopband within 200–1200 nm, excluding passband and transition zones
Design angle of incidence 0°
Outer diameter 25.00 ±0.10 mm
Clear aperture 22.5 mm
Thickness 3.30 ±0.20 mm
Substrate Optical glass
Surface quality 80-50
Coating Hard coating
Wide bandpass (LED-matched) Narrowband (10 nm) Transmission ↑ wider useful range (LED width + drift) FWHM ≈ 10 nm narrower = stronger rejection but may cut usable spectrum 750 780 810 850 870 890 910 Wavelength (nm) · illustrative, not a specific product ※ Design schematic, not measured data
Both at 850 nm: the wide solution keeps more LED spectrum, the narrow one rejects more — not interchangeable on center wavelength (design schematic)

Why can the bandwidth differ so much at the same 850 nm?

The 850 nm bandpass above is a wide solution matched to LED illumination; this example is a 10 nm narrowband interference filter. They address different signal-keeping and background-rejection needs.

A 10 nm filter may remove more out-of-band background, but it may also cut part of the LED spectrum; with wide-angle beams the passband shift must be evaluated. Filters cannot be interchanged on center wavelength alone.

Long pass and IR-cut filter specifications

Edge position (T=50% point) and its tolerance are the key specifications for these products.

Product direction Useful range Edge definition Edge parameters Peak transmission Surface quality
Near-IR long pass (780 nm edge) 800–1100 nm T=50% cut-on edge 780 nm, tolerance ±10 nm ≥90% 40/20
Visible transmission, UV/NIR rejection (double edge) 405–690 nm T=50% cut-on / cut-off edges 400 / 700 nm, tolerance ±15 nm ≥90% 40/20

Surface quality conditions for larger sizes are confirmed per specification.

Long pass filters

Long pass filters suit schemes that keep a wide near-IR range and reduce visible light. They do not keep only a narrow slice around the source like a narrowband filter, so background rejection must be judged against the ambient spectrum.

IR-cut filters

IR-cut filters are for imaging tasks that must keep visible light and reduce near-IR response. For color inspection they work together with white balance, illumination stability and color calibration — adding an IR-cut filter does not by itself guarantee accurate color.

Neutral density filters: exposure control

Neutral density filters state their attenuation in OD:

T = 10⁻ᴼᴰ

The table below is the nominal relation after mathematical conversion; it does not mean a given product achieves the same transmission at every wavelength.

Nominal OD Ideal transmission Intensity reduced to Typical use
0.3 50.1% 1/2 Light attenuation
0.6 25.1% 1/4 Moderate attenuation
0.9 12.6% 1/8 Stronger attenuation
1.0 10% 1/10 Bright targets
2.0 1% 1/100 Intense-light testing
3.0 0.1% 1/1000 Specific high-attenuation tasks

Reference specification example

Parameter Specification
Type Absorptive neutral density filter
Useful range 425–675 nm
Nominal OD 0.6
Average transmission 25%
Surface quality 40/20 (size exceptions confirmed per specification)

Attenuation of visible-range ND filters must not be extended to 850 nm or 940 nm directly. Near-IR attenuation tasks require the working band and flatness to be specified separately.

Polarizing filters: glare control

Polarizing schemes are often used to relieve part of the specular reflection from surfaces. A common arrangement places a linear polarizer at the source and a rotatable analyzer at the camera; adjusting their relative orientation changes the balance between glare and target information.

It also loses part of the useful light, and the result depends on material, angle and surface structure — complete elimination of all glare cannot be promised.

Polarizer (axis along the diagonal) Source LED / fiber P1 source polarizer linearly polarized sample surface glass / film / coating reflection (glare) P2 camera analyzer (rotatable) industrial camera Adjusting the P1–P2 orientation attenuates glare while keeping more target information; part of the useful light is lost (schematic)
Common arrangement with a source polarizer and a rotatable camera analyzer (design schematic)

A polarizer detail page should state the following parameters:

Parameter What must be specified
Working band Visible, near-IR or a specified band
Transmission Whether it applies to unpolarized light or to linearly polarized light along the transmission axis
Extinction ratio Measurement wavelength, angle and the definition used
Spectral consistency How transmission and extinction ratio vary with wavelength
Transmission axis Axis marking and mounting tolerance
Mounting Fixed or rotatable, with or without a locking mechanism
Clear aperture The area where optical performance is guaranteed
Temperature and intensity Determined by illumination power and environment

Polarizer transmission has different definitions, and extinction ratio must be evaluated with wavelength; a best value at one test point must not be presented as a guarantee for the whole band.

Common thread mount specifications

The table lists common mount directions for machine vision filter frames, useful when planning a companion series; actual delivery follows our own mechanical drawings.

Lens front thread Reference frame OD Reference clear aperture Reference overall thickness
M25.5 × 0.5 27.5 mm 21 mm 7 mm
M27 × 0.5 29 mm 22.5 mm 7 mm
M30.5 × 0.5 32.5 mm 25.5 mm 7 mm
M34 × 0.5 36 mm 29 mm 7 mm
M37 × 0.75 39 mm 31.9 mm 6.5 mm
M40.5 × 0.5 42.5 mm 35.5 mm 7 mm
M43 × 0.75 45 mm 38 mm 7 mm
M46 × 0.75 48 mm 41 mm 7 mm
M52 × 0.75 54 mm 47 mm 7 mm
M58 × 0.75 60 mm 52.9 mm 6.5 mm
Front view frame OD clear aperture (guaranteed) front thread Side section overall thickness filter (removable) Front filter thread ≠ C-Mount interface; actual dimensions follow our drawings (not to scale)
Four key dimensions of a threaded mount: thread, frame OD, clear aperture and overall thickness (design schematic, not to scale)

What to confirm

When selecting, confirm thread diameter, pitch, clear aperture, mounting depth and lens field of view at the same time. Front lens filter threads such as M25.5×0.5 are not the same specification as the C-Mount interface used to attach the lens to the camera.

Non-threaded lenses and internal mounting

For lenses without a front thread, sleeve mounting, dedicated brackets or bare-filter integration can be evaluated. When a filter is added inside the camera, focal plane, back focal length and mechanical interference must be checked.

Select by inspection task

Different tasks on the same line often call for different filter types first.

Inspection task First solution to evaluate Selection basis
Location / OCR under monochrome LED light Bandpass filter matched to the source Source spectral width, target reflection, ambient light
Laser-line / structured-light extraction Narrowband filter Laser drift, angle of incidence, target signal
Color appearance inspection Suitable IR-cut filter Camera internal filter, visible spectrum, color calibration
Near-IR imaging Near-IR bandpass or long pass Material response, camera sensitivity, background light
Glare masking surface features Source polarizer + lens analyzer Material, illumination geometry, light loss
UV reflection inspection UV bandpass filter UV transmission and response of lens and camera
UV-excited visible fluorescence Emission bandpass or suitable long pass Fluorescence emission spectrum, excitation blocking
Overexposure with the current aperture kept ND filter Working band, attenuation, flatness
Fluorescence label vs background Fluorescence filter set Excitation/emission separation, crosstalk control

Important distinction: "UV imaging" and "UV-excited fluorescence imaging" are not the same selection. The former may receive reflected UV light; the latter usually blocks the UV excitation and receives fluorescence at longer wavelengths.

Reading the specification sheet

Every term on a datasheet has a precise meaning — misreading one can derail the selection.

Center wavelength CWL

Locates the bandpass but does not describe the filter alone. Check the bandwidth, guaranteed transmission region and blocking range as well.

FWHM

The interval between the two wavelengths where transmission falls to half the peak. If peak transmission is 90%, half means 45% — not a fixed 50%.

Peak, average and minimum transmission

Peak describes only the highest point; average applies to a stated interval; minimum requires a defined lower limit within the region. "Peak ≥90%" must not be rewritten as "≥90% across the whole passband".

Blocking depth OD

OD4 corresponds to 0.01% transmission. The wavelength range and whether the value is average or minimum OD must be stated; the passband and transition zones are not part of the blocking guarantee.

Angle of incidence and cone angle

Interference filter spectra can shift with angle. Wide-angle lenses, large apertures or positions close to the sensor require the full field and beam angle distribution to be assessed.

Clear aperture

The region where optical performance is guaranteed — not the filter outer diameter, and not the mount thread diameter.

Customization and deliverables

Collect the inputs for the real inspection task, then agree the specification and deliverables.

Customization inputs

  • Light source model, center wavelength and actual emission spectrum.
  • Camera model, mono or color, detector response and internal filters.
  • Lens focal length, aperture, field of view and filter position.
  • Target, background, defect types and ambient light.
  • Dimensions, thread, operating temperature and cleaning method.

Specification agreement

Define the passband, blocking region, transmission, angular conditions and mechanical dimensions around the actual task; then confirm contrast, exposure margin and field uniformity with sample testing.

Deliverables

As agreed: spectral curves, dimension drawings, visual inspection, part and batch marking. High OD, environmental testing or special optical quality requirements need separately agreed test methods and acceptance criteria.

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide