Industrial inspection · Spectral & intensity control
Match the illumination band and make targets easier to detect
For industrial cameras, smart cameras, line-scan systems and inspection equipment: bandpass, long pass, IR-cut, polarizing and neutral density filter solutions matched to the light source wavelength, target material, ambient light and lens structure — supporting location, identification, measurement and defect detection.
A machine vision filter is an optical element installed at the illumination end, in front of the lens or inside the camera, used to shape the spectrum, polarization state or intensity of the light that forms the image.
An industrial camera simply records the light reaching the sensor; it cannot tell whether that light comes from the inspection source, factory lighting or surface reflections. By keeping the light that helps inspection and removing part of the unwanted light, filters make target features easier to separate.
The value usually lies in raising the distinguishability between target and background — not simply making the image brighter. Some tasks keep the light reflected by the target, while others work better with a darker target on a brighter background.
Source spectrum × Material reflection/emission × Filter transmission × Camera response
Knowing only "we use red light" or "we need ambient-light rejection" is not enough to specify a filter — the actual wavelength, source spectral width and imaging conditions must be confirmed.
Choose the filter type by inspection task first, then the detailed specifications.
| Type | Main role | Typical applications |
|---|---|---|
| LED-matched bandpass filters | Keep the illumination band, suppress part of the off-target light | Location, OCR, contour and defect detection |
| Narrowband interference filters | Select wavelengths within a narrow interval | Laser-line extraction, structured light, selected NIR imaging |
| Long pass filters | Transmit the usable band above the cut-on edge | NIR imaging, some fluorescence detection |
| IR-cut filters | Keep visible light, reduce near-IR response | Color recognition, appearance and color inspection |
| Polarizing filters | Select light by polarization state | Glare control on glass, film, coating and packaging surfaces |
| Neutral density filters | Reduce light intensity | Exposure control, imaging of bright targets |
| Fluorescence filter sets | Separate excitation from emission light | Glue, coating, oil and fluorescence-label detection |
The table lists reference specifications for common selection directions. "Useful range" follows common industry practice — it is not the FWHM and must not be read as peak transmission across the whole interval. Actual supply capability and measured performance follow our verified manufacturing and test results and the datasheet.
| Product direction | Typical LED sources | Useful range | FWHM | Peak transmission | Surface quality |
|---|---|---|---|---|---|
| Near-UV bandpass (365 nm) | 365 nm LED | 335–385 nm | 80 nm | ≥85% | 40/20 |
| Blue bandpass (470 nm) | 450 / 465 / 470 nm LED | 425–495 nm | 85 nm | ≥90% | 40/20 |
| Green bandpass (525 nm) | 520 / 525 / 530 nm LED | 500–555 nm | 80 nm | ≥90% | 40/20 |
| Light-red bandpass (635 nm) | 617 / 625 / 630 nm LED | 615–645 nm | 60 nm | ≥90% | 40/20 |
| Deep-red bandpass (660 nm) | 660 nm LED | 640–680 nm | 60 nm | ≥90% | 40/20 |
| Near-IR bandpass (850 nm) | 840 / 850 nm LED | 820–910 nm | 160 nm | ≥90% | 40/20 |
| 940 nm companion bandpass | 940 nm LED | 928–955 nm | 55 nm | ≥85% | 40/20 |
The surface quality grades above apply to the common size conditions; grades for larger sizes must be confirmed per specification and must not be extended to all sizes unconditionally.
365 nm: for imaging that receives near-UV light. If 365 nm excitation with visible fluorescence detection is used, the camera side usually needs the matching emission filter — a 365 nm bandpass cannot simply be reused.
470 nm / 525 nm: combine with blue or green illumination for surface or contrast inspection; the actual effect depends on the material.
635 nm / 660 nm: verify the actual wavelength of the red source — not all red illumination is the same specification.
850 nm / 940 nm: confirm the camera near-IR response and whether an internal IR-cut filter is present.
Out-of-band blocking depth must be confirmed per wavelength range for each product direction; the whole bandpass family should not be uniformly labelled with a single OD grade (e.g. OD4 or OD5).
Narrowband filters suit applications that need stronger spectral selectivity, but they must match the source spectral width and the actual angle of incidence. The industry-spec example below helps you understand the product parameter structure more clearly.
| Parameter | Example specification |
|---|---|
| Example type | 850 nm hard-coated narrowband interference filter (unmounted, industry-spec example) |
| Center wavelength CWL | 850 ±2 nm |
| FWHM | 10 ±2 nm |
| Transmission | ≥85% (minimum-transmission basis) |
| Average blocking OD | OD ≥4.0 |
| Blocking range | Specified stopband within 200–1200 nm, excluding passband and transition zones |
| Design angle of incidence | 0° |
| Outer diameter | 25.00 ±0.10 mm |
| Clear aperture | 22.5 mm |
| Thickness | 3.30 ±0.20 mm |
| Substrate | Optical glass |
| Surface quality | 80-50 |
| Coating | Hard coating |
The 850 nm bandpass above is a wide solution matched to LED illumination; this example is a 10 nm narrowband interference filter. They address different signal-keeping and background-rejection needs.
A 10 nm filter may remove more out-of-band background, but it may also cut part of the LED spectrum; with wide-angle beams the passband shift must be evaluated. Filters cannot be interchanged on center wavelength alone.
Edge position (T=50% point) and its tolerance are the key specifications for these products.
| Product direction | Useful range | Edge definition | Edge parameters | Peak transmission | Surface quality |
|---|---|---|---|---|---|
| Near-IR long pass (780 nm edge) | 800–1100 nm | T=50% cut-on edge | 780 nm, tolerance ±10 nm | ≥90% | 40/20 |
| Visible transmission, UV/NIR rejection (double edge) | 405–690 nm | T=50% cut-on / cut-off edges | 400 / 700 nm, tolerance ±15 nm | ≥90% | 40/20 |
Surface quality conditions for larger sizes are confirmed per specification.
Long pass filters suit schemes that keep a wide near-IR range and reduce visible light. They do not keep only a narrow slice around the source like a narrowband filter, so background rejection must be judged against the ambient spectrum.
IR-cut filters are for imaging tasks that must keep visible light and reduce near-IR response. For color inspection they work together with white balance, illumination stability and color calibration — adding an IR-cut filter does not by itself guarantee accurate color.
Neutral density filters state their attenuation in OD:
T = 10⁻ᴼᴰ
The table below is the nominal relation after mathematical conversion; it does not mean a given product achieves the same transmission at every wavelength.
| Nominal OD | Ideal transmission | Intensity reduced to | Typical use |
|---|---|---|---|
| 0.3 | 50.1% | 1/2 | Light attenuation |
| 0.6 | 25.1% | 1/4 | Moderate attenuation |
| 0.9 | 12.6% | 1/8 | Stronger attenuation |
| 1.0 | 10% | 1/10 | Bright targets |
| 2.0 | 1% | 1/100 | Intense-light testing |
| 3.0 | 0.1% | 1/1000 | Specific high-attenuation tasks |
| Parameter | Specification |
|---|---|
| Type | Absorptive neutral density filter |
| Useful range | 425–675 nm |
| Nominal OD | 0.6 |
| Average transmission | 25% |
| Surface quality | 40/20 (size exceptions confirmed per specification) |
Attenuation of visible-range ND filters must not be extended to 850 nm or 940 nm directly. Near-IR attenuation tasks require the working band and flatness to be specified separately.
Polarizing schemes are often used to relieve part of the specular reflection from surfaces. A common arrangement places a linear polarizer at the source and a rotatable analyzer at the camera; adjusting their relative orientation changes the balance between glare and target information.
It also loses part of the useful light, and the result depends on material, angle and surface structure — complete elimination of all glare cannot be promised.
| Parameter | What must be specified |
|---|---|
| Working band | Visible, near-IR or a specified band |
| Transmission | Whether it applies to unpolarized light or to linearly polarized light along the transmission axis |
| Extinction ratio | Measurement wavelength, angle and the definition used |
| Spectral consistency | How transmission and extinction ratio vary with wavelength |
| Transmission axis | Axis marking and mounting tolerance |
| Mounting | Fixed or rotatable, with or without a locking mechanism |
| Clear aperture | The area where optical performance is guaranteed |
| Temperature and intensity | Determined by illumination power and environment |
Polarizer transmission has different definitions, and extinction ratio must be evaluated with wavelength; a best value at one test point must not be presented as a guarantee for the whole band.
The table lists common mount directions for machine vision filter frames, useful when planning a companion series; actual delivery follows our own mechanical drawings.
| Lens front thread | Reference frame OD | Reference clear aperture | Reference overall thickness |
|---|---|---|---|
| M25.5 × 0.5 | 27.5 mm | 21 mm | 7 mm |
| M27 × 0.5 | 29 mm | 22.5 mm | 7 mm |
| M30.5 × 0.5 | 32.5 mm | 25.5 mm | 7 mm |
| M34 × 0.5 | 36 mm | 29 mm | 7 mm |
| M37 × 0.75 | 39 mm | 31.9 mm | 6.5 mm |
| M40.5 × 0.5 | 42.5 mm | 35.5 mm | 7 mm |
| M43 × 0.75 | 45 mm | 38 mm | 7 mm |
| M46 × 0.75 | 48 mm | 41 mm | 7 mm |
| M52 × 0.75 | 54 mm | 47 mm | 7 mm |
| M58 × 0.75 | 60 mm | 52.9 mm | 6.5 mm |
When selecting, confirm thread diameter, pitch, clear aperture, mounting depth and lens field of view at the same time. Front lens filter threads such as M25.5×0.5 are not the same specification as the C-Mount interface used to attach the lens to the camera.
For lenses without a front thread, sleeve mounting, dedicated brackets or bare-filter integration can be evaluated. When a filter is added inside the camera, focal plane, back focal length and mechanical interference must be checked.
Different tasks on the same line often call for different filter types first.
| Inspection task | First solution to evaluate | Selection basis |
|---|---|---|
| Location / OCR under monochrome LED light | Bandpass filter matched to the source | Source spectral width, target reflection, ambient light |
| Laser-line / structured-light extraction | Narrowband filter | Laser drift, angle of incidence, target signal |
| Color appearance inspection | Suitable IR-cut filter | Camera internal filter, visible spectrum, color calibration |
| Near-IR imaging | Near-IR bandpass or long pass | Material response, camera sensitivity, background light |
| Glare masking surface features | Source polarizer + lens analyzer | Material, illumination geometry, light loss |
| UV reflection inspection | UV bandpass filter | UV transmission and response of lens and camera |
| UV-excited visible fluorescence | Emission bandpass or suitable long pass | Fluorescence emission spectrum, excitation blocking |
| Overexposure with the current aperture kept | ND filter | Working band, attenuation, flatness |
| Fluorescence label vs background | Fluorescence filter set | Excitation/emission separation, crosstalk control |
Important distinction: "UV imaging" and "UV-excited fluorescence imaging" are not the same selection. The former may receive reflected UV light; the latter usually blocks the UV excitation and receives fluorescence at longer wavelengths.
Every term on a datasheet has a precise meaning — misreading one can derail the selection.
Locates the bandpass but does not describe the filter alone. Check the bandwidth, guaranteed transmission region and blocking range as well.
The interval between the two wavelengths where transmission falls to half the peak. If peak transmission is 90%, half means 45% — not a fixed 50%.
Peak describes only the highest point; average applies to a stated interval; minimum requires a defined lower limit within the region. "Peak ≥90%" must not be rewritten as "≥90% across the whole passband".
OD4 corresponds to 0.01% transmission. The wavelength range and whether the value is average or minimum OD must be stated; the passband and transition zones are not part of the blocking guarantee.
Interference filter spectra can shift with angle. Wide-angle lenses, large apertures or positions close to the sensor require the full field and beam angle distribution to be assessed.
The region where optical performance is guaranteed — not the filter outer diameter, and not the mount thread diameter.
Collect the inputs for the real inspection task, then agree the specification and deliverables.
Define the passband, blocking region, transmission, angular conditions and mechanical dimensions around the actual task; then confirm contrast, exposure margin and field uniformity with sample testing.
As agreed: spectral curves, dimension drawings, visual inspection, part and batch marking. High OD, environmental testing or special optical quality requirements need separately agreed test methods and acceptance criteria.