Infrared lenses work in the MWIR and LWIR; the material sets the usable band. Germanium covers roughly 2-14 μm, silicon 1.2-7 μm, zinc selenide 0.6-21 μm and is common in CO₂ laser optics, while zinc sulphide and chalcogenide glass serve special windows. These materials have a high refractive index and shift with temperature, so state the operating temperature and any athermalisation requirement together with the drawing.
| Materials | Ge, Si, ZnSe, ZnS, chalcogenide glass |
|---|---|
| Waveband | Material dependent: Ge ~2–14 μm, Si ~1.2–7 μm, ZnSe ~0.6–21 μm |
| Coating | Broadband IR AR, DLC hard coating on request |
| Aperture | φ5-φ100 mm (larger on project review) |
Typical processing ranges for this line. Requirements outside these can be evaluated to drawing; final specifications are confirmed by sample and datasheet.
Send the model or drawing — quote and lead time within one business day. Wavelength, bandwidth and size are all customisable.
Request a quote Browse all 0 models →
IN STOCK
Made to order — no stock models listed yet, ask about availability.
No matching models yet. Adjust the filters, or contact us for selection advice and samples.
Reset filters