ISO 9001 Certified Manufacturer 360° Factory Tour

Thermal imaging · IR transmission & window protection

Thermal Imaging Filters & Infrared Windows

Matching the IR working band while balancing imaging, temperature measurement and window protection

For MWIR and LWIR thermal imaging systems, we configure infrared AR windows, band-selecting filters, AR+DLC protective windows and dedicated spectral elements according to detector response, lens path and operating environment, supported by substrate fabrication, optical coating and inspection.

  • MWIR / LWIR
  • AR windows
  • Spectral selection
  • AR+DLC
  • Built to drawing
MWIR / LWIR Working band set by detector response
5 substrates Ge / Si / chalcogenide / ZnSe / ZnS
AR+DLC Combined AR and surface protection
Thermal camera lens, infrared window and thermal image combination
Window, lens and filter positions are schematic and vary between models

What is a thermal imaging filter?

A thermal imaging filter is a spectral control element in the infrared receiving path. It keeps the designated band, suppresses part of the non-target radiation, or reduces the radiation reaching the detector as required.

A thermal camera receives infrared radiation from the scene and converts it into an image. Temperature-measuring devices additionally need calibration, target emissivity, background reflection and optical-path transmission to calculate temperature.

In practice "thermal imaging filters" often appear together with "infrared windows", but the two have different emphases. The table compares element types by function and key metrics to help fix the combination.

Element type Main function Key metrics
IR AR window Protects internal optics while transmitting the working band Transmission, wavefront, thickness and environmental suitability
IR bandpass filter Limits the received band Passband, blocking range, angular response
IR attenuating filter Reduces received radiation intensity Spectral attenuation, temperature behaviour and calibration fit
Functional coating window Combines AR with surface protection Spectral performance, coating durability and assembly conditions
IR imaging lens Focuses radiation to form an image Surface figure, focal length, aberration and coating performance

An AR coating is not automatically a bandpass coating. A window with high 8–12 μm transmission does not therefore meet any specified OD blocking requirement outside that interval.

Scene (external) Inside the camera Scene IR radiation target + background atmospheric path External IR window protect + AR Imaging lens focuses the image Internal filter (optional) band select / attenuate IR detector cooled / uncooled set by response range Signal processing calibration / emissivity compensation Image / temperature Window and filter are part of the measuring path: re-check calibration and compensation after any change ※ The internal filter is fitted per model; some cameras only have a window and lens. The schematic does not fix the real layout
Scene IR radiation → external IR window → imaging lens → internal filter → detector → image / temperature output System position schematic: external window, imaging lens and internal filter each do their own job; the schematic does not fix the real optical layout.

Working band: match the detector first, then the filter

Band descriptions vary with the detector and lens combination; the directions below are common practice.

Scheme direction Typical band description Selection focus
MWIR Commonly designed around 3–5 μm Actual detector coverage, cryogenic or ambient mounting
LWIR Commonly designed around 8–12 μm or 8–14 μm Lens and detector response, band edges and window temperature
Dedicated narrow band Chosen within the detector response range Target material, gas or specific radiation feature
Attenuation scheme Controls transmission over a specified working interval High-radiance scenes, dynamic range and recalibration

Real response ranges differ between thermal imagers. For example, some FLIR cameras are specified at 7.5–14 μm, so an 8–12 μm window must not be treated as fully covering the working range of any "LWIR camera".

The working band should follow the actual detector, lens and system calibration requirements. The effective transmission range of the filter or window must cover the intended imaging band, and extra signal loss at the band edges must be checked.

Product options

Five families by element position and function; real projects often combine several.

Option A

LWIR AR window

Reduces surface reflection loss over the specified range in LWIR imaging paths, used as a front window, internal protective element or structural component. Germanium, chalcogenide and other suitable substrates can be assessed; material grade, thickness, operating temperature and imaging requirements decide the final choice.

Design focus
In-band transmission, transmitted wavefront, clear aperture, mounting and temperature conditions.
Option B

MWIR AR window

Materials and coating designs configured to the actual response of the MWIR detector and lens, with silicon and other suitable substrates for fabrication and coating.

Design focus
Passband coverage, substrate absorption, surface reflection and the real angle of use.
Option C

AR+DLC protective window

Combines AR with a DLC (diamond-like carbon) coating for windows with surface-durability requirements. DLC designs balance spectral transmission and surface protection; the presence of the coating does not by itself meet any specific sand/dust, scratch or environmental test level.

Design focus
Coating structure, transmission, adhesion and the agreed durability validation.
Option D

Band-selecting filter

Bandpass, longpass or shortpass responses set within the detector working range to limit the radiation taking part in imaging and measurement. Filters may sit in an ambient optical path or inside the cryogenic assembly; self-emission, reflection and temperature differ between positions and must be designed separately.

Design focus
Passband, blocking, angular distribution, operating temperature and self thermal background.
Option E

IR attenuating filter

For specific tests or high-temperature imaging that needs reduced received radiation. Attenuators change the system response and must not be chosen from a visible-light OD alone; the IR working range, attenuation versus wavelength and temperature, and whole-system calibration all need to be defined.

Design focus
Effective attenuation, spectral flatness, thermal load and dynamic-range matching.

The five options can be combined: one thermal camera may carry a front window, an internal band filter and a protective window at the same time, so each position is confirmed separately.

Infrared coating capability parameters

Existing material and coating directions for feasibility assessment; they are not out-of-band blocking specifications.

Substrate Band and coating Listed average transmission Product direction
Germanium Double-side AR, 8–12 μm ≥97% LWIR AR window
Germanium 4–12 μm coating ≈96% Broadband IR transmission element
Silicon 3–5 μm coating ≈98% MWIR transmission element
Germanium AR+DLC, 8–12 μm ≥91% LWIR protective window
Silicon AR+DLC, 3–5 μm ≥85% MWIR protective window
Chalcogenide glass 8–12 μm or 8–14 μm ≥96% LWIR transmission element
Zinc selenide (ZnSe) AR coating Per specific design IR windows and optics
Zinc sulfide (ZnS) AR coating Per specific design IR windows and optics

Chalcogenide glasses include grades such as IRG201, IRG202, IRG204, IRG205 and IRG206; band and performance are confirmed per grade, thickness and coating design.

Average transmission does not mean every wavelength in the interval reaches that value. The approximate figures are kept as listed; test conditions and guaranteed values are fixed at product acceptance.

① Coating structure (cross-section) Substrate (Ge / Si …) AR stack DLC layer (outer face) ※ Positions and layer counts follow the coating design; not to scale ※ DLC presence does not by itself meet sand/dust, scratch or environmental test levels ② Spectral transmission (schematic) AR AR+DLC ≥97%(所列) ≥91%(所列) 6 8 – 12 14 Wavelength (μm) · schematic ※ Directional schematic, not measured data; acceptance per grade, thickness and coating
AR+DLC coating structure schematic: AR combined with diamond-like carbon (design schematic)

Material fabrication capability

Lapping/polishing and single-point diamond turning are listed separately for lens and optical component evaluation.

Material Lapping & polishing aperture SPDT aperture Surface figure PV
Germanium (Ge) φ4–200 mm φ4–300 mm 0.1–0.6 μm
Silicon (Si) φ4–200 mm φ4–200 mm 0.1–0.6 μm
Chalcogenide glass φ4–140 mm φ4–180 mm 0.1–0.6 μm
Zinc selenide (ZnSe) φ4–200 mm φ4–200 mm 0.1–0.6 μm
Zinc sulfide (ZnS) φ4–200 mm φ4–200 mm 0.1–0.6 μm

These are fabrication ranges by material and process. Thickness, aperture, figure and accuracy combinations for a specific window or lens are confirmed per drawing; the maximum aperture does not imply the highest accuracy everywhere at once.

For imaging windows, transmitted wavefront, parallelism or wedge should also be specified as needed beyond single-surface figure. Surface figure PV alone does not describe the full imaging impact.

Detailed specification items for filters and windows

Parameters to confirm item by item; concrete values follow drawing evaluation and validated fabrication and inspection results.

Parameter To be specified Why it matters
Working band Start/end wavelengths in actual use Matched to detector and lens coverage
Spectral function AR, bandpass, longpass, shortpass or attenuating Separates windows from band-selecting functions
Passband transmission Minimum, average or point transmission For assessing effective radiative loss
Out-of-band blocking Wavelength interval with transmission limit or OD Defined only for filter schemes with blocking requirements
Cut-on / cut-off edge Position, criterion and tolerance Affects response at the edges of the working band
Incidence conditions Chief ray angle, beam cone and polarisation For assessing the spectral behaviour across the field
Operating temperature Ambient, cryogenic or other real range Affects spectrum, thermal background and structure
Material and thickness Grade, thickness and tolerance Affect absorption, strength and focal position
Clear aperture Region over which optical performance is guaranteed Keeps mechanical and optical apertures separate
Surface quality Scratches, digs and inspection conditions Corresponds to surface defect control
Figure and wavefront Metric type, clear aperture and evaluation method For assessing image-quality impact
Parallelism or wedge Value and direction Balances beam deviation and ghost-image control
Coating durability Adhesion, cleaning and environmental tests Corresponds to the real service environment
Delivery records Spectra, dimensions, appearance and agreed inspection reports Forms a traceable acceptance basis

Out-of-band blocking is defined only for filter schemes that need it; AR windows normally specify the working interval and transmission without OD terminology.

Samples in germanium, silicon, chalcogenide glass, ZnSe and ZnS
Photographs of germanium, silicon, chalcogenide and other material elements
Si 3–5 μm (≈98%) Ge 8–12 μm (≥97%) Avg. transmission 3 5 8 12 Wavelength (μm) · schematic, not to scale ※ Directional schematic, not measured data; state substrate, coating, band and test conditions
Spectral curve example: substrate, coating, band and test conditions noted (schematic, not presented as measured data)
1 Lapping & polishing up to φ4–200 mm 2 Diamond turning up to φ4–300 mm 3 Coating AR / AR+DLC stacks 4 Inspection figure / spectrum / cosmetics Material and process combinations are assessed per drawing; figure PV and aperture accuracy are confirmed separately ※ Process stages are schematic, not a single line sequence; delivery follows the specification sheet
Fabrication gallery: lapping/polishing, SPDT, coating and inspection equipment

Impact on imaging and temperature measurement

Transmission, window temperature and band selection all change system behaviour; five points to settle at design stage.

Point1

Higher transmission does not automatically mean better measurement accuracy

Higher transmission helps preserve the target signal, but measurement results also depend on calibration, emissivity, background reflection and environmental conditions. After changing to a window with different transmission, check whether the existing compensation parameters still apply.

Point2

Window temperature matters as well

A window transmits target radiation but can also emit its own thermal radiation and reflect the background. Some measurement cameras provide correction based on external window transmission and temperature, which shows the window must be treated as part of the measuring path.

Point3

NETD is not measurement accuracy

NETD describes the ability to distinguish small temperature differences, not the absolute error of the temperature reading. Signal loss from a filter can affect thermal sensitivity, but whole-system NETD cannot be computed from the transmission of a single element.

Point4

Wide fields need edge-ray checks

For interference filters, changes in the real incidence angle can shift or reshape the passband. Evaluate the entire field together with the lens and mounting position instead of checking only the normal-incidence curve.

Point5

Narrower bands reduce received radiation

Dedicated filters improve selectivity for certain spectral features while reducing total signal. Optical gas imaging and similar applications must co-design the filter, detector sensitivity and background contrast.

① Scene field of view (instrument) FOV 90° (example) detector Not directly equal lens / window position optics / baffling clear aperture ② Real incidence angle at the filter (component) filter field edge θ2 other side θ3 on axis θ1 normal Angular suitability must be confirmed with the complete optics: 90° scene FOV ≠ unchanged filter performance at ±45°
Field-edge incidence angle and passband shift (design schematic, not measured curves)

Windows and filters are part of the measuring path: after any change, re-validate with system calibration and compensation rather than comparing single-element transmission alone.

Application directions

Band, environment and integration requirements differ by application, and so do the component priorities.

Application Main need Component focus
Industrial inspection thermal imagers Stable imaging and temperature measurement LWIR transmission, window compensation and durability
Online IR thermography cameras Continuous operation Contamination, drift, cleaning and batch consistency
Compact thermal imaging modules Miniaturised integration Thickness, clear aperture and assembly space
Outdoor thermal imaging devices Environmental robustness Window protection, humidity/heat and contamination
Scientific MWIR thermal systems Specific bands and high-speed measurement Bandpass design, filter wheels and temperature conditions
Special-material temperature measurement Selecting a suitable radiation band Material spectra and system calibration
Optical gas imaging Selecting gas-related spectral regions Narrowband response, thermal background and system sensitivity

Special-material measurement and gas imaging need dedicated spectral and system validation; ordinary broadband AR windows must not substitute dedicated filters.

Custom process

System requirement → material & coating → opto-mechanical design → sample inspection → system validation → specification release

  1. 1

    Define the system

    Camera model, detector band, measurement or observation use.

  2. 2

    Choose the option

    AR window, protective window, band filter or attenuating element.

  3. 3

    Match the structure

    Size, thickness, mounting position, field of view and operating temperature.

  4. 4

    Inspect samples

    Spectra, dimensions, appearance and agreed figure or wavefront.

  5. 5

    Validate in system

    Image quality, uniformity, thermal sensitivity and temperature compensation.

  6. 6

    Release the specification

    Batch tolerances, inspection conditions and record requirements.

Frequently asked questions

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included