Matched to the colour path: illumination spectrum and detection band

For portable, benchtop and in-line colour measurement systems. Working from the illumination source, the dispersion structure, the detector response and the sample behaviour, we design UV-cut, out-of-band rejection, channel selection and intensity-control filters for material colour measurement and optical module integration.

  • UV condition control
  • Visible spectral matching
  • Out-of-band rejection
  • Module integration
UV control Prerequisite for fluorescent samples
Illumination / detection Two positions, two functions
Batch consistency A variable in the final dE result
Colorimeter, colour charts and optical filter elements (product visual)
Path and element positions are schematic and vary between models

What is a colorimeter filter?

A colorimeter filter is a spectral-selection or intensity-control element in a colour measurement path. By changing transmission, reflection or absorption in specific bands it adjusts the spectrum reaching the sample, or limits the spectral range entering the detector.

A spectrophotometric colorimeter first acquires the spectral information of the sample as a function of wavelength, then computes tristimulus values and colour parameters under the selected standard illuminant and standard observer. It therefore provides not only a colour difference number but also the spectral data behind it.

In a typical grating colorimeter the grating and array detector carry the main dispersion and detection function. The filter supports UV control, non-target band suppression or intensity adjustment; such an instrument should not be described simply as "measuring colour with red, green and blue filters".

Two colour measurement approaches have to be distinguished:

Approach Basic characteristics Typical filter function
Spectrophotometric colour Measures spectral information at many wavelengths, then computes colour parameters Illumination spectrum control, out-of-band rejection, order sorting, auxiliary selection
Tristimulus colour Approximates tristimulus values through several weighted response channels Forms the target channel response together with source and detector

This page covers the spectrophotometric approach. Instruments that use filter-based tristimulus channels are described on the colour difference meter filter page; the two should not share one set of specifications.

Measurement principle: from reflectance spectrum to colour parameters

A filter does not change colour itself; it changes the spectrum illuminating the sample and the spectrum reaching the detector.

  1. 01

    The source illuminates the sample

    The spectrum the sample receives is set by the source and the illumination path together. A filter on the illumination side changes the UV, visible or other content reaching the sample.

  2. 02

    Light is collected under the defined geometry

    The instrument collects reflected light according to its illumination and viewing design. The measurement geometry determines how diffuse and specular components are handled and is essential for comparability.

  3. 03

    Light is dispersed and recorded per wavelength

    The collected light enters the detector through the dispersion system. With reference calibration the system obtains the spectral measurement result.

  4. 04

    Colour and colour difference are computed

    For non-fluorescent samples, XYZ can be computed from the spectral reflectance, the specified illuminant spectrum and the standard observer colour matching functions, then converted to L*a*b* and similar parameters. Comparing sample and standard gives the colour difference using the agreed formula.

Illumination side · sets the excitation Detection side · sets what the detector sees Source incl. UV Illum. filter UV cut-off Sample reflect + emit Collection geometry Dispersion grating Array detector per wavelength Reflectance × illuminant × observer → XYZ → L*a*b* / dE ① Illumination-side filters change the excitation; detection-side filters change what the detector sees ② Visible fluorescence already emitted cannot be blocked by a detection-side UV-cut filter
Illumination source → illumination-side filter → sample → collection optics → dispersion and filter assembly → detector → spectral and colour computation A schematic of reflection colour measurement; element positions vary with the instrument structure.

Filter elements on the illumination side and the detection side do different jobs: one sets the light the sample receives, the other sets the light the detector sees. Mixing their specifications is the most common source of error in colorimeter filter selection.

Core concept: why control the UV content?

With fluorescent samples, colour measurement is no longer pure reflection — it becomes reflection plus emission.

Paper, textiles and plastics may contain fluorescent whitening agents or other fluorescent components. These materials absorb shorter wavelengths and can emit fluorescence at longer wavelengths, so the light collected by the instrument may contain both reflected light and fluorescence.

When the UV content of the illumination changes, the degree of fluorescent excitation can change as well, affecting whiteness, chromaticity and colour difference. For such samples, matching only the visible detection band is not enough to guarantee the same measurement conditions.

A UV-cut filter can reduce a specified UV range in the illumination; systems with UV adjustment also need source control, reference materials and calibration methods to define the actual condition. Instruments differ: some use a mechanical filter change, others use multiple sources or numerical processing.

Illumination side

Illumination side: sets the excitation

A filter on the illumination side determines how much UV reaches the sample. It changes the emission condition of the sample and therefore directly affects the result for fluorescent materials.

Detection side

Detection side: sets what is received

A filter on the detection side changes which wavelengths reach the detector. It does not change how much the sample was already excited — only how much light gets through.

Visible fluorescence already generated in the sample cannot be removed by a UV-cut filter on the detection side. This is where the two positions are most often confused.

With UV in illumination UV-cut illumination Fluorescence emission band Intensity nm raised by emission reflection only 400 500 600 700 Wavelength (nm) ※ Schematic, not measured data; actual emission depends on excitation and sample
UV conditions compared: the same fluorescent sample under UV-containing and UV-cut illumination (design schematic, not measured data)

Product options: choosing the structure by optical function

The structures below are grouped by where they sit and what they solve; the combination depends on the instrument architecture and the sample behaviour.

Option A

Illumination-side UV-cut filter

Reduces transmission over a specified UV range while keeping the visible light required, for UV exclusion or UV condition adjustment. The design has to consider UV suppression, the cut-off edge and short-wave visible transmission; an edge that reaches too far into the visible region can also change blue-violet illumination conditions.

Selection focus
UV cut-off range, transition band, visible transmission range, mounting position.
Option B

Visible transmission with NIR rejection

Keeps the visible measurement range required and reduces the share of non-target NIR entering the detection channel. Whether it is needed depends on source output, detector response and the existing dispersion system; an instrument that "measures visible colour" cannot be assumed to be unaffected by non-visible bands.

Selection focus
Visible passband, red-edge transition, NIR cut-off, effective signal loss.
Option C

Order-sorting filter

For dispersion structures affected by higher-order overlap, suppressing non-target light that may overlap the target band. Its form and position depend on whether the architecture is scanning or array based; in an array system that detects a wide band at once, a single long-pass element cannot simply block short wavelengths when those wavelengths are also measurement targets.

Selection focus
Dispersion architecture, target coverage, order overlap positions, channel arrangement.
Option D

Multi-channel bandpass filter set

For colour modules that use a filter array, a filter wheel or another multi-channel selection method, sampling the spectrum with several passbands. Channel count, bandwidth, overlap and the following algorithm all affect spectral reconstruction and the colour result; a few broad channels do not equal full spectrophotometric capability.

Selection focus
Individual channel response, out-of-band rejection, channel consistency, system calibration.
Option E

Neutral density filter

Attenuates intensity over a specified range for detector dynamic-range matching, reference channel adjustment or a test path. Colour work also needs the spectral flatness of the attenuation: a large wavelength-dependent difference can change the received spectral balance and has to be handled in design and calibration.

Selection focus
Attenuation level, spectral flatness, reflection behaviour, long-term stability.
UV cut-off NIR rejection Multi-channel bandpass Transmission nm UV blocked three channels NIR falls off 400 700 1000 Wavelength (nm) ※ Schematic of three structures, not measured data; edges and bandwidth by agreement
Spectral characteristics compared: UV cut-off, NIR rejection and multi-channel bandpass (design schematic, not measured data)

The five options are not mutually exclusive: one instrument may use illumination-side UV cutting and detection-side rejection at the same time, so each position should be confirmed separately.

Customisation parameters and fabrication notes

The table lists the parameters to confirm item by item; fabrication ranges and performance figures are confirmed against the project requirement and validated fabrication and inspection results.

Parameter Customisation Explanation
Position Illumination side, detection side, reference channel or inside the dispersion assembly The function differs with the position
Working band Set by the actual spectral coverage of the instrument A single "visible range" is not applied universally
Spectral structure UV cut-off, NIR cut-off, bandpass or neutral density Selected according to the system goal
Cut-off edge Position, criterion and permitted deviation State the transmission level used to define the edge
Passband transmission Minimum, average or peak Defined separately; the three cannot be interchanged
Passband flatness Transmission variation within a specified interval Affects spectral shape and channel response
Out-of-band rejection Transmission limit or OD over a specified range Not equivalent to the colour difference accuracy of the instrument
Channel bandwidth FWHM and guaranteed passband Applies to bandpass parts and multi-channel sets
Incidence conditions Chief ray angle, angular spread and polarisation Spectral shift assessed against the actual path
Substrate and thickness Spectral fit, mechanical strength, process compatibility Substrate absorption and possible self-fluorescence also matter
Outline and clear aperture Per holder, filter wheel or array drawing Distinguish the outline from the guaranteed optical area
Surface and edge Surface defects, chamfer and edge requirements Agreed by scatter sensitivity and assembly need
Environment and lifetime Temperature, humidity, light exposure and cleaning Assesses long-term spectral change
Inspection and delivery Spectral curves, dimensions and batch documents State test conditions and acceptance method

Colorimeter filters require spectral performance and batch consistency together. A high transmission on one sample does not mean that different batches will give the same colour result once installed. The released specification should define the critical spectral intervals, tolerances and inspection conditions, with an acceptable range confirmed by instrument validation.

clear aperture Single element outline vs clear aperture Filter wheel set repeatability and order window Window integration datum and sealing ※ Three delivery forms by assembly; dimensions, coated face and orientation per drawing
Three delivery forms: single element, filter wheel set and window integration (structure schematic; dimensions per drawing)

Clarifications: four pairs that are often confused

These four come up most often in colorimeter filter discussions, and are most often treated as the same thing.

Q1

Spectral sampling interval versus spectral bandwidth

The sampling interval is how often the instrument reports a data point along wavelength; the spectral bandwidth is the wavelength range a single measurement channel actually receives. They are different figures, and a smaller interval does not automatically mean higher real spectral resolution.

Q2

SCI / SCE versus the filter

SCI includes the specular component and SCE excludes it. They concern the measurement geometry and how specular reflection is handled; they are not two filter colours and cannot be achieved simply by changing a bandpass element.

Q3

Standard illuminant versus the physical source

Selecting D65 for the calculation does not mean the instrument contains a physical source with exactly that spectrum. For non-fluorescent samples the colour can be computed under the specified illuminant from the measured reflectance; for fluorescent samples the actual excitation conditions also have to be considered.

Q4

Filter performance versus instrument colour difference

Filter transmission, OD or centre wavelength tolerance cannot be converted directly into an instrument dE. The result also depends on the source, measurement geometry, wavelength accuracy, detector, calibration and sample condition.

Applications and adaptation points

Requirements differ widely with the material measured; fluorescence is the first dividing line.

Application Typical samples Filter design focus
Textile colour measurement Dyed and optically brightened fabrics UV conditions, fluorescence effects, batch consistency
Paper and print colour measurement Paper, board, printed patches Fluorescent whitening agents, illumination conditions, spectral response
Plastics and coatings Plastic parts, masterbatch, coatings Visible spectral matching, geometry, stability
Benchtop colorimeters Laboratory material samples Spectral purity, reference channel, calibration fit
Portable colorimeters On-site colour difference checks Compact size, assembly consistency, environmental robustness
In-line colour inspection Continuously produced material Long-term light stability, thermal drift, maintenance conditions

For metallic, pearlescent and other effect materials, the filter has to be assessed together with a multi-angle measurement structure; a single filter arrangement rarely covers colour that changes with viewing angle.

Custom process

Requirement review → spectral design → mechanical adaptation → sample inspection → instrument validation → specification release

  1. 1

    Define the measurement task

    Reflection or transmission, sample type, and whether fluorescent components are present.

  2. 2

    Establish the instrument structure

    Source, dispersion method, detector and filter mounting position.

  3. 3

    Set the spectral targets

    Passband, blocking regions, edges, tolerances and working angle.

  4. 4

    Match the mechanical structure

    Thickness, clear aperture, fixing method and switching mechanism.

  5. 5

    Validate sample performance

    Check spectra and test typical, dark and applicable fluorescent reference samples.

  6. 6

    Release the production specification

    Agree batch consistency, inspection conditions and delivery documents.