ISO 9001 Certified Manufacturer 360° Factory Tour

Product Category / Chalcogenide · 1-14 μm

Chalcogenide Glass Lenses

Infrared Lenses Customized to spec →
MaterialsChalcogenide glass (molded / polished) Wavebandapprox. 1-14 μm Apertureφ5-φ100 mm (larger on project review)

Selection & customization

  • Covers 1-14 μm broadband IR
  • Precision-moldable aspheres at volume
  • Low thermal drift, lightweight
  • Suited to IR lens mass production
Chalcogenide glass lenses are used for focusing, collimating and imaging infrared light, typically in 3–5 μm mid-wave infrared (MWIR) and 8–12 μm long-wave infrared (LWIR) systems. Chalcogenide glass is available in several grades, and the material composition determines its transmission range, refractive index, dispersion and temperature behaviour. Taking SCHOTT IRG 26 as an example, its refractive index at 10 μm is about 2.78. When selecting, check the internal transmission of the substrate at the actual lens thickness, and use the transmission of the finished, coated lens as the acceptance criterion. Aspheric fabrication and AR coatings Chalcogenide glass can be ground and polished, single-point diamond turned, or precision moulded. For infrared objectives that must control spherical aberration and shorten the lens assembly, an aspheric design should be evaluated. At the prototype stage, single-point diamond turning can be chosen according to the surface type and quantity; once the design is fixed, precision moulding can be evaluated against lens size, surface accuracy and production volume. The infrared anti-reflection (AR) coating should be designed for the source, the detector and the band the system actually uses, for example 3–5 μm or 8–12 μm. If a long-wave system must extend to 14 μm, check the transmission curve of the chosen grade specifically between 12 and 14 μm, and specify the minimum transmission within the band. For wide-field or large-aperture systems, also provide the range of incidence angles on the lens surface so that the coating specification can be set. Typical applications
ApplicationRole of the chalcogenide lensSelection focus
LWIR thermal imagingImages the target's thermal radiation onto the detectorOperating band, focal length, field of view and imaging quality across the full temperature range
Infrared thermometryConcentrates the radiation from the target area onto the detectorMeasurement distance, target spot size and actual lens temperature
Infrared gas analysisCouples the beam into the gas cell, or focuses the transmitted light onto the detectorTarget gas absorption band, reference channel and coating transmission
Compact IR lens assembliesUses aspheric surfaces to correct aberrations and keep the assembly compactClear aperture, back focal length, surface accuracy and assembly tolerances
Operating temperature range and mounting method Some chalcogenide grades have a low temperature coefficient of refractive index (dn/dT), which makes them suitable for passive athermal design. The actual focus drift also depends on the thermal expansion of the lens, on how optical power is distributed among the elements, and on the axial displacement of the barrel and spacers as temperature changes. For a fixed-focus system, check the focus position at the lowest, nominal and highest operating temperatures. If a retaining ring or adhesive bonding is used, also assess the assembly clearance and lens stress over temperature cycling. For custom selection, please provide the operating band, the transmission requirement after coating, the lens outer diameter and clear aperture, the focal length at the design wavelength, the lens operating temperature range and the mounting method. If an optical drawing is available, also include the material grade, centre thickness, aspheric coefficients, barrel material and permitted defocus, so that the material, fabrication process, coating and temperature compensation can be evaluated.

Customization capabilities

Materials Chalcogenide glass (molded / polished)
Waveband approx. 1–14 μm
Aperture φ5-φ100 mm (larger on project review)
Coating Broadband IR AR

Typical processing ranges for this line. Requirements outside these can be evaluated to drawing; final specifications are confirmed by sample and datasheet.

Quick quote

Send the model or drawing — quote and lead time within one business day. Wavelength, bandwidth and size are all customisable.

Request a quote Browse all 0 models →
Chalcogenide Glass Lenses — customization capabilities, coated to your drawing
Made to drawing · CWL / bandwidth / size

IN STOCK

Partially in stock

See models below ↓

Made to order — no stock models listed yet, ask about availability.

0 models found

No matching models yet. Adjust the filters, or contact us for selection advice and samples.

Reset filters
Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide