ISO 9001 Certified Manufacturer 360° Factory Tour

Product Category / ZnS · 0.4-12 μm

Zinc Sulfide Lenses

Infrared Lenses Customized to spec →
MaterialsZinc sulfide (CVD multispectral) Wavebandapprox. 0.4-12 μm Apertureφ5-φ100 mm (larger on project review)

Selection & customization

  • Covers 0.4-12 μm visible and IR
  • Hard, scratch and weather resistant
  • Suited to airborne and outdoor use
  • Multispectral CVD grade available
Zinc sulfide lenses are made from optical-grade zinc sulfide (ZnS) for focusing, collimating and imaging infrared light. The standard infrared grade (FLIR grade) is commonly used in long-wave infrared thermal imaging, while the multispectral grade suits systems that need visible-light alignment or a shared visible and infrared optical path. Taking multispectral ZnS as an example, the reference transmission range of the substrate is about 0.37–13.5 μm, with a refractive index of about 2.20 at 10 μm. The transmission of a finished lens depends on the material grade, the lens thickness and the coating design. Material grades and coating selection
Material gradeTypical useSelection focus
Standard infrared grade (FLIR grade)LWIR thermal imaging, infrared thermometryFinished transmission within the target band, lens thickness and surface quality
Multispectral gradeVisible-light alignment, shared visible and IR path, multi-band inspectionMinimum transmission per channel, short-wave scatter and multi-band coating requirements
Multispectral ZnS is normally hot isostatically pressed (HIP) to improve transmission in the visible and short-wave infrared. At near-normal incidence in air, an uncoated ZnS surface reflects about 14% per side at 10 μm. LWIR lens assemblies can use an 8–12 μm anti-reflection (AR) coating designed around the detector response. If the system must cover up to 14 μm, check the transmission between 12 and 14 μm at the actual lens thickness in particular. For projects that share a visible and infrared path, state the operating band and the minimum transmission of each channel separately. Typical applications
ApplicationRole of the ZnS lensSelection focus
LWIR thermal imagingImages the target's thermal radiation onto the detectorOperating band, focal length, field of view and imaging quality across the full temperature range
Shared visible and infrared pathProvides focusing or relay imaging for several spectral channelsTransmission per channel, focal-plane position and channel-to-channel registration
Infrared thermometryConcentrates the thermal radiation from the target area onto the detectorMeasurement distance, target spot size and actual lens temperature
Infrared spectroscopy and gas analysisCouples infrared light into the sample, gas cell or detectorTarget absorption band, clear aperture and coated transmission
Operating temperature range and mounting method Temperature changes alter the refractive index of ZnS, and thermal expansion of the barrel and spacers also changes the distance between the lens and the detector. For a fixed-focus system, evaluate the focus shift across the full temperature range using the thermo-optic data of the material at the design wavelength, the barrel material and the permitted defocus. Multispectral systems sharing one optical path should also verify the focal-plane position of each channel separately. If a retaining ring or adhesive bonding is used, assess mounting stress against the assembly clearance and the temperature-cycling conditions. For custom selection, please provide the operating bands, the minimum transmission for each band, the material grade, the lens outer diameter and clear aperture, the focal length at the design wavelength, the operating temperature range and the mounting method. If a drawing is available, also include the radii of curvature, centre thickness and back focal length. For multispectral shared-path projects, state which channels are used for alignment and which for imaging, so that the material grade, coating specification and focal-plane tolerances can be determined.

Customization capabilities

Materials Zinc sulfide (CVD multispectral)
Waveband approx. 0.4–12 μm
Aperture φ5-φ100 mm (larger on project review)
Coating Broadband IR AR

Typical processing ranges for this line. Requirements outside these can be evaluated to drawing; final specifications are confirmed by sample and datasheet.

Quick quote

Send the model or drawing — quote and lead time within one business day. Wavelength, bandwidth and size are all customisable.

Request a quote Browse all 0 models →
Zinc Sulfide Lenses — customization capabilities, coated to your drawing
Made to drawing · CWL / bandwidth / size

IN STOCK

Partially in stock

See models below ↓

Made to order — no stock models listed yet, ask about availability.

0 models found

No matching models yet. Adjust the filters, or contact us for selection advice and samples.

Reset filters
Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide