ISO 9001 Certified Manufacturer 360° Factory Tour
Video coming soon — the transcript is below
Selection Guide

Specifying a Narrowband Filter: Five Parameters in Order

1k plays · · 04:12

About this video

Why do narrowband filter quotes keep going back and forth? Because the parameters have no order. Here is the five-step sequence we use internally, ending with a checklist you can copy.

Full Transcript

Narrowband filters are the product we re-quote most often — not because they cannot be made, but because the requirement has no priority order. Here is the five-step method we use internally.

Step one, fix the centre wavelength. Give a number and a tolerance, and say where it comes from: a fluorophore emission peak or a laser line. An emission peak is a broad envelope, so the value depends on your detection window, not the peak point. Plus or minus two nanometres is common; precision fluorescence needs plus or minus one.

Step two, choose the bandwidth. This is the core trade-off. Signal scales with bandwidth, and so does background — but for a narrow signal on a continuum, narrowing the band suppresses background faster than it costs signal. Start from half the Stokes shift, then tune against measured signal-to-noise.

Step three, specify blocking depth and range. OD is a log scale: OD3 is one part in a thousand, OD6 one in a million. Saying OD6 alone is not enough — state the band and the value at the excitation wavelength. Leaked excitation is usually the dominant background and needs an order of magnitude more rejection.

Step four, confirm the angle of incidence. Interference coatings shift blue at oblique incidence: one to two nanometres at ten degrees, more than eight at twenty-five. A converging f/2 beam reaches fifteen degrees at the margin, so the measured curve will be wider and bluer. Either pre-compensate the centre wavelength or add a collimating lens.

Step five, substrate, thickness and size. B270 is cheap and general, fused silica handles UV and heat, sapphire resists scratches. Thin substrates suit compact modules but are sensitive to mounting stress. Automated lines usually want plus or minus zero point zero five millimetres and a zero point two by forty-five degree chamfer.

One last warning: for humid, salt-spray or thermal-cycling environments, specify a hard coating and an adhesion standard — do not just write "to sample".

Need a custom optical filter?

Send us your drawing and spectral targets — an engineer replies with a feasibility check and quotation within one business day.

Source Factory In-house coating lines, no middlemen
Ready to Ship Standard items dispatched same or next day
Quality Guaranteed 100 % inspected, spectral report included
Express Delivery DHL / FedEx worldwide