Original content by the OOTEE Optics editorial team, drawn from first-hand production line and inspection data. Please credit the source when republishing.
Given limits in expertise and test conditions, the theories, parameters and conclusions here carry no guarantee of absolute accuracy. For technical learning and exchange only - never the sole basis for design, acceptance or selection. Corrections welcome.
Batch consistency describes how much the parameters agree between parts of one batch - center wavelength, bandwidth, transmission, blocking depth. A per-part tolerance guarantees each piece lands inside a range; batch consistency demands that they also agree with each other.
Those are two different things. With a tolerance of +/-3 nm, part A at 529 nm and part B at 535 nm are both compliant - yet in an eight-channel instrument those two channels will never match.
| Metric | Meaning | Typical requirement |
|---|---|---|
| Within-batch CWL range | Maximum minus minimum in one batch | 1-2 nm or less (narrowband) |
| Within-bandwidth range | Maximum minus minimum FWHM | Within 10% of nominal |
| Within-transmission range | Maximum minus minimum peak transmission | 3-5 percentage points |
| Batch-to-batch offset | Difference of typical values between batches | Same as within-batch, or agreed separately |
Distinguish within-batch from batch-to-batch: the first affects multiple channels in one instrument; the second decides whether a reorder six months later drops in without recalibration.
Conversely, for a single instrument using one part with individual calibration, the requirement can relax and the screening cost stays in your pocket.
The first two raise process cost, the third raises inspection cost. Every step up in consistency shows up in the quotation. Decide which parameters genuinely affect your system.
Do not stop at the per-part tolerance - add a within-batch clause:
"Per part: CWL 531 +/- 1 nm. Within-batch consistency: CWL spread no more than 1.0 nm, bandwidth spread no more than 1 nm, peak transmission spread no more than 3 percentage points within one batch. Supply full inspection data with each batch."
That last sentence matters: it lets you verify before assembly rather than trace problems afterwards.
Balancing consistency against cost? Send channel count, mounting method and calibration workflow to sales@ootee.cn for binning options and pricing tiers.
365nm Narrow Bandpass Filter | Ø50mm | T>90%
OT-HBP3659050
365nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
450nm Narrow Bandpass Filter | Ø50mm
OT-HBP4509050
450nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
525nm Narrow Bandpass Filter | Ø50mm
OT-HBP5259050
525nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
Send us your drawing and spectral targets — an engineer replies with a feasibility check and quotation within one business day.