Original content by the OOTEE Optics editorial team, drawn from first-hand production line and inspection data. Please credit the source when republishing.
Given limits in expertise and test conditions, the theories, parameters and conclusions here carry no guarantee of absolute accuracy. For technical learning and exchange only - never the sole basis for design, acceptance or selection. Corrections welcome.
Coating durability describes how well a film survives wiping, damp heat, salt fog and temperature change. It does not appear on the spectral curve, yet it decides how long the part lasts once installed.
Many "sample passes, production fails gradually" stories trace back to exactly this.
| Test | Typical condition | What is checked |
|---|---|---|
| Adhesion (tape test) | Specified tape applied and pulled off sharply | Peeling or detachment of the film |
| Abrasion | Cloth or eraser rubbed for a set number of strokes at set pressure | Scratches and film damage |
| Damp heat | e.g. 40 C / 90% RH for 48-240 hours | Wavelength drift, transmission change, appearance |
| Thermal cycling | e.g. -40 C to +85 C for 5-50 cycles | Cracking, delamination, wavelength drift |
| Salt fog | 5% NaCl fog for 24-96 hours | Corrosion and discoloration |
| Solvent resistance | Wiping with alcohol, acetone and similar | Dissolution or hazing of the film |
Typical governing standards include MIL-C-48497 (US military coating standard), the ISO 9211 series for optical coatings and GB/T 26332 in China, plus sector-specific standards.
Many vendors only inspect appearance. What really matters is the spectral comparison before and after:
Ask for before-and-after measured curves - the most convincing evidence available.
Three elements, none optional: standard + condition or duration + pass threshold.
Example: "Per the relevant ISO 9211 / MIL-C-48497 tests: after 96 hours at 40 C and 90% RH, center wavelength drift no more than 0.5 nm, peak transmission loss no more than 2%, no peeling or pitting; after 20 cycles from -40 to +85 C, no cracking or delamination."
A sentence like "must be durable" carries no obligation at all and will not be acted on.
Need a test plan for your application? Send the environment, temperature and humidity range and lifetime target to sales@ootee.cn.
365nm Narrow Bandpass Filter | Ø50mm | T>90%
OT-HBP3659050
365nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
450nm Narrow Bandpass Filter | Ø50mm
OT-HBP4509050
450nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
525nm Narrow Bandpass Filter | Ø50mm
OT-HBP5259050
525nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
Send us your drawing and spectral targets — an engineer replies with a feasibility check and quotation within one business day.