Original content by the OOTEE Optics editorial team, drawn from first-hand production line and inspection data. Please credit the source when republishing.
Given limits in expertise and test conditions, the theories, parameters and conclusions here carry no guarantee of absolute accuracy. For technical learning and exchange only - never the sole basis for design, acceptance or selection. Corrections welcome.
Angle of incidence (AOI) is the angle between the incoming ray and the surface normal of the filter, in degrees. Normal incidence is AOI 0 degrees.
It is the hidden premise of every spectral figure on a datasheet. That beautiful curve was almost certainly measured at 0 degrees; tilt the filter in your instrument and the whole curve moves. This is the number one cause of "the sample passed, the machine does not work".
Interference filters select wavelength through interference inside the layers, and interference depends on the effective optical path. At an angle the geometric path inside a layer lengthens while the component along the normal shrinks - effectively the layers look optically thinner, so the wavelength that satisfies constructive interference moves shorter. That is the blue shift.
At small angles a handy approximation applies:
lambda(theta) approx lambda0 times the square root of (1 - sin-squared theta divided by n_eff squared)
with n_eff the effective index of the stack, typically 1.5-2.0 for visible narrowband filters. Hence:
For the full derivation and compensation methods, see angular shift.
Real optical paths are rarely perfectly collimated. The cone behind a lens, the output of a fiber, or the Lambertian spread of an LED all mean light arrives over a range of angles. Three consequences:
That is why flat-top filters perform better in high numerical aperture systems - there is no peak to shave off in the first place.
| Component | Typical AOI | Note |
|---|---|---|
| Bandpass / narrowband filter | 0 degrees (occasionally +/-5-10) | Keep it normal; compensate if tilted |
| Dichroic mirror / beam splitter | 45 degrees | Nominal wavelength is meaningless without the angle |
| Mirror | 0 or 45 degrees | Dielectric mirrors are angle sensitive too |
| Fluorescence filter set | 0 degrees (dichroic at 45) | Excitation and emission filters normal, dichroic tilted |
Recommended wording: "CWL 532 +/- 1 nm at AOI 0 degrees; actual use at AOI 0 +/- 8 degrees (converging beam)". With the second half, the maker can decide whether to apply angular compensation or switch to a flat-top design.
Not sure what equivalent AOI your optical path imposes? Send a sketch of the layout to sales@ootee.cn and we will estimate the angular distribution and propose compensation.
365nm Narrow Bandpass Filter | Ø50mm | T>90%
OT-HBP3659050
365nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
450nm Narrow Bandpass Filter | Ø50mm
OT-HBP4509050
450nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
525nm Narrow Bandpass Filter | Ø50mm
OT-HBP5259050
525nm Narrow Bandpass Filter; FWHM 10nm; transmission >90%; blocking OD5; size Ø50mm; AOI 0°.
Send us your drawing and spectral targets — an engineer replies with a feasibility check and quotation within one business day.